Modes; Test Mode - Compulite Luna User Manual

Yokes
Table of Contents

Advertisement

L u n a a n d N o va Y o k e s

Modes

Mode
DMX address
Velocity control
Resolution
Mode
Horizontal start
point
Horizontal end
point
Vertical start
point
Vertical end point
Focus start point
Focus end point
Display
orientation
*Each press on an arrow key increases or decreases the value by approximately 4
degrees.
**Each press on an arrow key initiates 1 turn of the motor. From 0 – FL there are 25
turns.

Test Mode

Test can be initiated when the Yoke is at rest or when it is moving. Travel stops
when any key is pressed.
There is a default wait of 5 seconds from the time Test mode is selected and
initiation of the test to give the operator time to get clear of the yoke.
The test lasts for 10 minutes or until any button is pressed.
Keypresses
1. Press MODE until
COM is displayed
2. Press any key except
MODE.
3. Press any key to exit
Test.
Doc. Version 1.01
Display
Purpose
D###
Set the yoke's DMX address
FAST or
Determine the movement speed. Use
SLOW
Slow for the most accurate positioning.
8-b or 16-b
Choose 8-bit or 16-bit resolution.
COM or TEST
COM is the usual operational mode.
TEST puts the yoke through its Test
routine.
XL##
Define the start point for pan. *
XH##
Define the end point for pan. *
YL##
Define the start point for tilt. *
YH##
Define the end point for tilt. *
FL##
Define the beginning of the focus path.
**
FH##
Define the end of the focus path. **
⇓⇓⇓⇓ or
Adjust the display according to the
⇑⇑⇑⇑
physical placement of the yoke –
hanging or standing.
Results/Comments
The Yoke goes to Test mode.