2-3. Baffle Plate for the Outdoor Unit

(CLxx models only)
NOTE
It is recommended to use baffle plates for models
CL1872 and CL2472. The baffle plates are not normally
required for the other models.
When the outdoor unit is installed in a position exposed
to strong wind (like seasonal winds with low air tempera-
ture in winter), baffle plates must be installed in front of
the outdoor unit. (Fig. 5f)
This unit is designed so that the fan of the outdoor unit
runs at low speed when the air conditioner is operated at
low outdoor air temperatures. When the outdoor unit is
exposed to strong wind, the system pressure drops
because of the freeze protector.
Baffle
plate
Air discharge
6
6" min
Fig. 5f
Baffle
plate