Outdoor Unit; Baffle Plate For The Outdoor Unit - Sanyo CMH3172A Installation Instructions Manual

Inverter multi split system air conditioner
Hide thumbs Also See for CMH3172A:
Table of Contents

Advertisement

2-3. Outdoor Unit

AVOID:
G
heat sources, exhaust fans, etc. (Fig. 5a)
G
damp, humid or uneven locations.
DO:
G
choose a place as cool as possible.
G
choose a place that is well ventilated.
G
install in a location where at least two sides are unob-
structed, so that the flow of air at the intake port or
exhaust port is not blocked, and so that sufficient
space is ensured for maintenance to be carried out
without trouble. In general the top also must be unob-
structed. (Fig. 5b)
G
provide a solid base (level concrete pad, concrete block,
6" × 1'4" (15 × 40 cm) beams or equal), a minimum of 6"
(15 cm) above ground level to reduce humidity and
protect the unit against possible water damage and
decreased service life. (Figs. 5c and 5d)
A solid base must not cover
CAUTION
the hole of the bottom plate.
G
install cushion rubber under unit's feet to reduce vibration
and noise. (Fig. 5e)
G
use lug bolts or equal to bolt down unit, reducing vibration
and noise.
G
install in a location where no antenna of a television or
radio exists within 10' (3 m).

2-4. Baffle Plate for the Outdoor Unit

NOTE
It is recommended to use baffle plates.
When the outdoor unit is installed in a position exposed to
strong wind (such as seasonal winds with low air tempera-
ture in winter), baffle plates must be installed on the outdoor
unit. (Fig. 5f)
This unit is designed so that the fan of the outdoor unit runs
at low speed when the air conditioner is operated at low
outdoor air temperatures. When the outdoor unit is exposed
to strong wind, the system pressure drops because of the
freeze protector.
Install a pair of windbaffle plates at the front and back of the
outdoor unit if it will be subject to strong wind during the
winter. (Figs. 5f, 5g, 5h, 5i, and 5j)
NO
Hot air
Outdoor unit
Fig. 5a
Air intake
Min. 8" (20 cm)
Min.
Air discharge
4" (10 cm)
Air intake
Concrete
or equal
Air intake baffle
Wind
Back
No air intake baffle required on this side.
10
Exhaust fan
Heat source
Obstacle above
Min.
7' (2 m)
Valve
side
Min. 10"
(25 cm)
Min.
1'8" (50 cm)
Ground
Min. 8" (20 cm)
Air intake
Fig. 5b
Drain holes
Fig. 5c
Anchor bolts
(4 pcs.)
Min. 6" (15 cm)
Fig. 5d
Cushion rubber
Fig. 5e
Front
Wind
Air discharge baffle
Fig. 5f
Min.
7' (2 m)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents