8-6. Cold draft Prevention (Heating)

This function controls indoor fan speed so a strong draft of cold air will not blow out before the indoor heat
exchange coil have sufficiently warmed up.
STANDBY lamp on front of the indoor unit lights up when this function is working.
when 10 minutes has elapsed,the fan speed is automatically switched to set speed regardless of indoor heat
exchange coil temperature.
Indoor heat exch.
coil temp. (¡F)
Max. 10minutes
95
77
Indoor fan
OFF
Standby lamp
ON
Set speed
LL
OFF
51