6. ELECTRICAL DATA

6-1. Electrical Characteristics

Cooling
(1) Indoor unit
KS0951
Outdoor unit C0951 / CL0951
115V single-phase 60Hz
Performance at
Rating conditions
Full load conditions
Rating conditions:
Indoor air temperature
Outdoor air temperature
Full load conditions: Indoor air temperature
Outdoor air temperature
(2) Indoor unit
KS1251
Outdoor unit C1251 / CL1251
115V single-phase 60Hz
Performance at
Rating conditions
Full load conditions
Rating conditions:
Indoor air temperature
Outdoor air temperature
Full load conditions: Indoor air temperature
Outdoor air temperature
(3) Indoor unit
KS1852
Outdoor unit C1852 / CL1852
230 / 280V single-phase 60Hz
Performance at
Rating conditions
Full load conditions
Rating conditions:
Indoor air temperature
Outdoor air temperature
Full load conditions: Indoor air temperature
Outdoor air temperature
Running amp.
A
Power input
kW
Running amp.
A
Power input
kW
80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
95°F (35°C) D.B.
95°F (35°C) D.B. / 70°F (21.2°C) W.B.
115°F (46.1°C) D.B.
Running amp.
A
Power input
kW
Running amp.
A
Power input
kW
80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
95°F (35°C) D.B.
95°F (35°C) D.B. / 70°F (21.2°C) W.B.
115°F (46.1°C) D.B.
Running amp.
A
Power input
kW
Running amp.
A
Power input
kW
80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
95°F (35°C) D.B.
95°F (35°C) D.B. / 70°F (21.2°C) W.B.
115°F (46.1°C) D.B.
Indoor Unit
Fan Motor
Fan Motor
115V single-phase 60Hz
0.40
0.655
0.034
0.075
0.4
0.655
0.034
0.075
Indoor Unit
Fan Motor
Fan Motor
115V single-phase 60Hz
0.40
0.704
0.034
0.081
0.4
0.704
0.034
0.081
Indoor Unit
Fan Motor
Fan Motor
230 / 208V single-phase 60Hz
0.25 / 0.23
0.498 / 0.465
0.047 / 0.045
0.113 / 0.095
0.25 / 0.23
0.498 / 0.465
0.047 / 0.040
0.113 / 0.095
26
Outdoor Unit
Complete Unit
Compressor
7.7
0.79
9.4
1.04
Outdoor Unit
Complete Unit
Compressor
9.8
1.09
12.2
1.41
Outdoor Unit
Complete Unit
Compressor
7.1 / 7.7
1.56 / 1.53
8.6 / 9.5
1.93 / 1.96
8.8
0.90
10.5
1.15
10.9
1.20
13.3
1.52
7.8 / 8.4
1.72 / 1.67
9.3 / 10.2
2.09 / 2.10