Product description
The pms sensor has a stainless steel
housing and is designed for applica-
tions with hygienic requirements.
The ultrasonic transducer surface of
the pms sensors is laminated with a
PTFE film. The transducer itself is
sealed against the housing by a joint
ring.
The pms sensor with D12 adapter
shaft can be fitted in a mounting clip
which meets hygiene standards like
Operating Instructions
the sensor srew connection BF-pms/
A1.
Ultrasonic proximity switch with
The special housing design ensures
one switched output
that any cleaning fluids are able to
run off completely, regardless of the
pms+15/CF/A1
installation situation.
The pms sensor is ECOLAB certified.
pms+25/CF/A1
pms+35/CF/A1
The pms sensor variant D12 adapter
shaft offers a non-contact measure-
pms+100/CF/A1
Sensor adjustment with Teach-in procedure
Set detect point
Set detect point +8 %
– method A
– method B
Place object at position
Place object at position
Connect Com for about
Connect Com for about
3 s to +U
3 s to +U
B
Connect Com for about
Connect Com for about
1 s to +U
3 s to +U
B
ment of the distance to an object
present within the sensors's detec-
tion zone. The switched output is set
conditional upon the adjusted detect
distance.
For sensor setting, the accessory
LinkControl adapter LCA-2 is recom-
mended in combination with Link-
Control software for Windows©. Al-
ternatively, the sensor can also be set
by Teach-in via pin 2.
The pms sensors are IO-Link-capable
in accordance with IO-Link specifica-
tion V1.1.
Safety Notes
Read the operating instructions
prior to start-up.
Connection, installation and ad-
justment works should be carried
out by expert personnel only.
Set two way reflective
Set window mode
barrier
Install reflector at
Place object at position
position
Connect Com for about
Connect Com for about
3 s to +U
3 s to +U
B
B
Place object at position
Connect Com for about
Connect Com for about
1 s to +U
10 s to +U
B
B
Normal operating mode
Set switched output
No
safety
component
accordance with the EU Machine
Directive.
Proper Use
pms ultrasonic sensors are used for
non-contact detection of objects.
The sensor must be mounted in an
EHEDG-approved
mounzing
such as the sensor screw connection
BF-pms/A1 for a EHEDG-complaint
use.
Installation
Assemble the sensor and its hygi-
enic D12 sensor screw connection
BF-pms/A1 or an equivalent sensor
mounting clip at the instation lo-
cation.
Pull sensor cable through the sen-
sor gland, connect it to the M8
Set NOC/NCC
Connect Com for about
13 s to +U
B
B
To change output
characteristic connect
B
Com for about 1 s to +U
B
Wait for 10 s
in
sensor plug.
Push the sensor with its shaft into
the sensor screw connection BF-
ms/A1 and adjust (see figure 4-6).
Tighten with lock nut (maximum
tightening torque 12 Nm).
2
1
clip,
3
5
4
colour
1
+U
brown
B
3
-U
blue
B
4
F
black
2
Com
white
Fig. 1: Pin assignment with view onto sensor
plug and colour coding of the
microsonic connection cables
Start-up
Connect the power supply.
Carry out sensor adjustment with
Reset to factory setting
Switch off operating
voltage
Connect Com to -U
B
Switch on
operating voltage
Keep Com connected to
-U
for about 13 s
B
Disconnect Com from -U
B
before switching off supply
voltage
Normal operating mode
Further Settings
LinkControl or alternatively Teach-
in procedure in accordance with
the diagram.
HM-1809
Factory Setting
Detect point operation
Switched output on NOC
Detect distance at operating range
Filter at F01
Filter strength at P00
Operating Modes
Three operating modes are available
for the switched output:
Operation with one detect point
The switched output is set when the
object falls below the set detect
point.
Window mode
The switched output is set when the
object is within the set window.
Two-way reflective barrier
The switched output is set when the
object is between sensor and fixed
reflector.
≥0.25 m
≥1.30 m
pms-15
≥0.35 m
≥2.50 m
pms-25
≥0.40 m
≥2.50 m
pms-35
≥0.70 m
≥4.00 m
pms-100
Fig. 2: Assembly distances
Maintenance
microsonic sensors are maintenance-
free. For cleaning in areas with hygi-
enic requirements, access to the sen-
sor must be guaranteed from all
sides. Cleaning is permitted up to a
cleaning temperature of 85°C. Do
not use a high-pressure cleaner to
clean the sensor.
Notes
The sensors of the pms family
have a blind zone, within which a
distance measurement is not pos-
sible.
If several pms sensors are operated
in a small space, the minimum
mounting for parallel or opposite