Microsonic lcs+340/DD Operating Manual

Ultrasonic proximity switch with two switched outputs

Advertisement

Quick Links

Product description
The lcs+ sensor offers a non-contact
measurement of the distance to an
object which must be positioned within
the sensor's detection zone. The swit-
ched outputs are set conditional upon
the adjusted detect distances.
Via the Teach-in procedure, the detect
distances and operating modes can
be adjusted. Two LEDs indicate opera-
tion and the state of the switched
outputs.
Operating manual
Optionally all Teach-in and additional
sensor parameter settings can be
Ultrasonic proximity switch with
made using the LinkControl Adapter
two switched outputs
LCA-2 (optional accessory) and the
LinkControl software for windows.
lcs+340/DD
Safety instructions
lcs+600/DD
Read the operating instructions
prior to start-up.
Sensor adjustment with Teach-in procedure
Adjust detect
Adjust detect
Adjust window
point D1-
point + 8 % D1 -
mode D1
method A
method B
Place object at
Place object at
Place object at
position 1.
position 1.
position 1.
Press T1 for about
Press T1 for about
Press T1 for about
3 s until both LEDs
3 s until both LEDs
3 s until both LEDs
flash simultaneously.
flash simultaneously.
flash simultaneously.
Both
flash
Both
flash
Both
LEDs:
mutually
LEDs:
mutually
LEDs:
Place object at
position 2.
Both
LEDs:
Press T1 for about
Press T1 for about
Press T1 for about
3 s until both LEDs
1 s.
1 s.
flash mutually again.
Normal mode operation
Set switched output D1
Connection, installation and ad-
justments may only be carried out
by qualified staff.
No safety component in accordance
with the EU Machine Directive.
Use for intended purpose only
lcs+ultrasonic sensors are used for
non-contact detection of objects.
Installation
Mount the sensor at the place of
fitting.
Connect a connection cable to the
M12 device plug.
Start-up
Connect the power supply.
Carry out sensor adjustment in
accordance with the diagram.
Adjust two-way
Set NOC/NCC D1
reflective barrier D1
Place reflector at
position 1.
Press T1 for about
Press T1 for about
3 s until both LEDs
13 s until both LEDs
flash simultaneously.
flash mutually.
flash
Both
flash
LED D2:
flashes
mutually
LEDs:
mutually
LED D1:
on: NOC/
off: NCC
flash
mutually
Press T1 for about
To change output
10 s until both LEDs
characteristic press T1
stop flashing.
for about 1 s.
Wait for 10 s.
Set switched output
2
1
3
5
4
colour
1
+U
brown
B
3
-U
blue
B
4
D2
black
2
D1
white
5
Sync/Com
grey
Fig. 1: Pin assignment with view onto sensor
plug and colour coding of the
microsonic connection cables
Factory setting
Switched output on NOC.
Detect distance at operating range
and half operating range.
Adjust detect
Adjust detect
Adjust window
point D2 -
point + 8 % D2-
mode D2
method A
method B
Place object at
Place object at
Place object at
position 1.
position 1.
position 1.
Press T2 for about
Press T2 for about
Press T2 for about
3 s until both LEDs
3 s until both LEDs
3 s until both LEDs
flash simultaneously.
flash simultaneously.
flash simultaneously.
Both
flash
Both
flash
Both
flash
LEDs:
mutually
LEDs:
mutually
LEDs:
mutually
Place object at positi-
on 2.
Both
flash
LEDs:
mutually
Press T2 for about
Press T2 for about
Press T2 for about
3 s until both LEDs
1 s.
1 s.
flash mutually again.
Normal mode operation
Set switched output D2
Synchronisation
Notes
If under multiple sensor operation
The sensors of the lcs+ family have
the assembly distance falls below the
a blind zone, within which a dis-
values shown in Fig. 2, the internal
tance measurement is not possi-
synchronisation should be used. For
ble.
this purpose interconnect each pin 5
The lcs+ sensors are equipped
of max. 10 sensors.
with an internal temperature com-
pensation. Due to the sensor's self
heating, the temperature compen-
sation reaches its optimum work-
ing-point after approx. 30 minutes
≥ 2.00 m
≥ 18.00 m
of operation.
≥ 4.00 m
≥ 30.00 m
During normal operation a yellow
LED signals that the corresponding
output has connected.
Fig. 2: Assembly distances
If no push-buttons are pressed for
Maintenance
20 seconds during parameter set-
microsonic sensors are maintenance-
ting mode the made changes are
free. In case of excess caked-on dirt
stored and the sensor returns to
we recommend cleaning the white
normal mode operation.
sensor surface
Adjust two-way
Activate/deactivate
Set NOC/NCC D2
reflective barrier D2
Place reflector at
Turn supply voltage
position 1.
While pressing T1
turn supply voltage
Press T2 for about
Press T2 for about
Press T1 for about
3 s until both LEDs
13 s until both LEDs
3 s until both LEDs
flash simultaneously.
flash mutually.
flash simultaneously.
Both
flash
LED D1:
flashes
LED D2:
LEDs:
mutually
LED D2:
on: NOC/
LED D1:
off: NCC
Press T2 for about
To change output
To activate or deacti-
10 s until both LEDs
characteristic press T2
vate Teach-in press T1
stop flashing.
for about 1 s.
Wait for 10 s.
Further Settings
Reset to factory
Teach-in
setting
Turn supply voltage
OFF.
OFF.
While pressing T1
turn supply voltage
ON.
ON.
Press T1 for about
13 s until both LEDs
flash mutually.
flashes
on: Teach-in
activated
off: Teach-in
deactivated
for about 1 s.
Wait for 10 s.
Normal mode operation
Further settings

Advertisement

loading
Need help?

Need help?

Do you have a question about the lcs+340/DD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Microsonic lcs+340/DD

  • Page 1 Detect distance at operating range Maintenance 20 seconds during parameter set- Connect the power supply. and half operating range. microsonic sensors are maintenance- ting mode the made changes are lcs+340/DD Safety instructions Carry out sensor adjustment in free. In case of excess caked-on dirt...
  • Page 2 *B10634* microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E info@microsonic.de / W microsonic.de The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not confirm any product features.

This manual is also suitable for:

Lcs+600/dd