Product Part No:
• Universal Controller
Features:
• Controls and monitors Dyadic case
• Genus or alternative network compatible
• Full defrost control
Associated Documents:
∗ Datasheet:
∗ DIN Box Display:
∗ Set-up Unit:
∗ Using Probe Clips:
∗ Health and Safety:
Please Note:
The features and specifications contained in this
Installation Guide may change without notice.
Elm Ltd. shall not be liable for errors or for incidental or
consequential damages in connection with the
furnishing, performance or use of this product or
document.
Controller
(Fig. 2)
Alarm wired to Relay 5 N/C
contact if bit switch 3 is ON
Fans
Defrost heater
Compressor B
Compressor A
Mains
Supply
190797-YAD
ZD 10001-YAD
ZF 0920-DIN
ZF 0795-DAD
ZG 56003
ZG 1056
Plant fault 2
Plant fault 1
white
Case lights /
blinds
CN6
Relay
5
CN5
Relay
4
CN4
Relay
3
CN3
Relay
2
CN2
Relay
1
YAD
CN1
E
L
N
CN7
Controller on a
Woodley Network
Note: This simplified wiring diagram omits circuit protection
Bit Switch Settings (Fig. 1) : (Shaded area = Switch Position)
Genus Network
Elm Probes
Relay 5 switches lights
Not used....leave off
Dyadic case option
Not used....leave off
red
green
CN15
CN14
P1
CN13
CN12
CN11
CN10
CN9
8
7
Bit switches
6
5
4
3
2
1
ON
P2
CN8
CN7
Controller on a
white
Genus Network
black
screen
Universal Controller - YAD
Issue a :5/11/96
Warning !
Before you work on this equipment, isolate the
electrical supply and also the live feed to any
incoming signals. Remember that live signals
may be derived from more than one source
Off
On
1
Alternative Network
2
Alternative Probes
3
Relay 5 Switches Alarm
4
Not used....leave off
5
6
7
8
Not used....leave off
Position of probes should be in accordance
Temperature Probes -
with case manufacturers instructions
(P6) Logging
(P5) Honeycomb
(P4) Evaporator out
(P3) Evaporator in
(P2) Air off
(P1) Air on
Defrost
PAGE
SELECT
PAGE
HOME
5k
10k
OPTIONS
Fans
Case
Normal
only
off
Setup unit extension cable
red
white
yellow
green
-1.5
blue
Ent
DIN Box Display
green
black
white
red
screen
Previous
controller
Genus or alternative
Network cable
Dyadic
ZA-10005-YAD
.
+
Setup
Unit
EXECUTE
Alarm
Network
Defrost
Esc
Next
controller