Can Connections - Curtis Acuity 1030 Manual

Battery monitoring system
Table of Contents

Advertisement

2 — INSTALLATION & WIRING

CAN connections

The CAN connector is either a 2-pin Deutsch or two bullet-style connectors.
Note that the Deutsch connector is not acid resistant, and therefore if used
should be located at least one meter away from the battery.
The termination resistors on a cable should match the nominal impedance
of the cable. ISO 11898 requires a cable with a nominal impedance of 120 Ω;
therefore, you should use 120 Ω resistors for termination. If you place multiple
devices along the cable, only devices at the ends of the cable need termination.
You can specify whether the Acuity will include the 120 Ω termination resistor
(see Specifications, page 28).
5
Curtis 1030 Acuity Manual,
Rev. C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents