Device Parameter Objects; Table 2 Device Parameter Objects - Curtis Acuity 1030 Manual

Battery monitoring system
Table of Contents

Advertisement

7 — DEVICE PARAMETER OBJECTS
7
INDEX
SUB-INDEX ACCESS
5100h
5101h
5102h
5103h
5105h
5106h
5107h
5108h
5109h
510Ah
510Bh
510Ch
5111h
5112h
5113h
5114h
20

DEVICE PARAMETER OBJECTS

SDOs can be used to set up battery-specific parameters such as battery system
voltage and rated capacity. They can also be used to set up battery operation
related parameters such battery depth of discharge, charge full voltage, etc.
The objects found in the 5100h CAN Object address range are shown
in Table 2. Definitions follow the table.

Table 2 Device Parameter Objects

BYTE 5 BYTE 6
00h
RW
LSB
00h
RW
LSB
00h
RW
LSB
00h
RW
#
01h
RW
#
02h
RW
#
00h
RW
value
00h
RW
#1
00h
RW
LSB
00h
RW
LSB
00..11h
RW
00h
RW
BC_Lth BC_Hth 'B'
00h
RW
HRint
00h
RW
CAN
Prcl
00..15
RW
0
00h
RW
pdo1
00h
RW
'R'
00h
RW
sec
01h
RW
day
02h
RW
DoW
BYTE 7 BYTE 8
MSB
'B'
'V'
Battery Voltage. 16-bit value. Keyword: BV
MSB
'A'
'h'
Manufacturer Ah Rating, at 5hr or 6hr.
Keyword: Ah.
MSB
'T'
'y'
Battery Profile parameters.
Keyword: Ty.
#
#
#
#### = Battery ID bytes 12..9.
#
#
#
#### = Battery ID bytes 8..5.
#
#
#
#### = Battery ID bytes 4..1.
'D'
'O'
'D'
Depth of Discharge.
#2
'C'
'E'
#1 = Charge Efficiency at high rates.
#2 = Charge Efficiency at low rates.
MSB
'C'
'F'
Charge Full, in mVPC.
MSB
'S'
'O'
Current Sensor Offset, in mA.
Custom discharge parameters; see Definitions.
'C'
Battery Cycle Thresholds, low and high.
Range 0 –100.
'H'
'R'
'I'
Historical Record store interval; range 0 –3.
0=1/8C, 1=1/16C, 2=1/24C, 3=1/32C.
'C'
'P'
'L'
CAN protocol for V.I.T. time; range 0 –2.
0=CANopen PDO. 1=J1939 proprietary.
2=3100R.
0
0
0
Customer notes. Total of 64 bytes.
Addressable 4 bytes at a time, using
sub-indexes 1–15.
pdo2 heartB
'F'
PDO1, PDO2, and Heartbeat Tx frequency.
Resolution 100 ms. Value of 0 disables PDO.
'n'
'g'
#
Sets binned Ah range. For low range, set
Byte8 to 0h. For high range, set Byte8 to 1h.
min
hour
'T'
Time of day.
month year
'D'
Date.
0
0
'W'
Day of week. (Sunday = 1)
DESCRIPTION
Curtis 1030 Acuity Manual,
Rev. C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents