Installation And Wiring; Mounting The Module; Fig . 2: Mounting Dimensions - Curtis Acuity 1030 Manual

Battery monitoring system
Table of Contents

Advertisement

2
Fig. 2
Mounting
dimensions, Curtis 1030
Acuity.
Curtis 1030 Acuity Manual,

INSTALLATION AND WIRING

The outline and dimensions for the 1030 Acuity are shown in Figure 2.
Perform the installation in an area that is well ventilated. Before
installing the Acuity module, clean the battery, cables, and terminals.
M O D E L 1 0 3 0
D I M E N S I O N S m m
47
ALLOWABLE
MENISCUS
3mm MAX
30
Dimensions in millimeters
Rev. C
54
SEE NOTE 2
26
CURRENT SENSOR
Arrow shows direction
of discharge current
940±15
44
179
125±15
605±15
POWER
CABLES
CAN CONNECTOR
B+ : Red
Pin 1 & Pin 2
B– : Black
960±15
TEMP SENSOR
CABLE
5/16" RING
TERMINALS
TYP 3X
2 — INSTALLATION & WIRING
NOTES:
1. Case & Current Sensor Housing
Material: Glass- lled PBT.
2. Current Sensor can accomodate
most cable sizes up to 4/0.
3. Current Sensor to be held to
battery cable by tie-wraps
(2 places).
4. Acid resistant tie-wraps should
be used to secure unit.
5. This unit not tted with a CAN
termination resistor.
CAN CONNECTOR
PIN 1: CAN Hi — White Mates
with Molex 19038-0001.
PIN 2: CAN Low — Black mates
with Molex 19034-0005.
3

Hide quick links:

Advertisement

Table of Contents
loading