5. In the junction box, with a wire nut, tie the white common wires together. Using the green ground
screw, ground the green wire from the fan and the 2 wire Romex from the thermostat, to the junction
box. Tie the black wire from the fan to the taped white wire from the thermostat. Tie the black wire
from the power source to the black wire from the thermostat. Replace the cover on the junction box.
6. In the themostat, tie the black wire to one of the black wires from the thermostat. Tie the taped wire
to the other black wire from the thermostat. Using the ground screw in the thermostat, ground the
ground wire from the 2 wire Romex.
7. Tie the two remaining black wires together. Then, tie the remaining copper wires together.
Figure 3.2B: Thermostat Wiring in a Remote Location
®
®
ADVANCED ATTIC GABLE FANS
ADVANCED ATTIC GABLE FANS
Specialty Series Fan
Specialty Series Fan
Power Source
Power Source
1-888-QUIETCOOL
Ground the fan to the junction box
Ground the fan to the junction box
using the green ground screw
using the green ground screw
Junction
Junction
Box
Box
14-2 Wire
14-2 Wire
14-2 Wire
14-2 Wire
Thermostat
Thermostat
FAN ON
FAN ON
TEMPERATURE
TEMPERATURE
90°
90°
60°
60°
60°
60°
120°
120°
®
®
ADJUSTABLE
ADJUSTABLE
TEMPERATURE THERMOSTAT
TEMPERATURE THERMOSTAT
CAUTION
CAUTION
Automatically started device - to reduce the
Automatically started device - to reduce the
risk of injury disconnect from power supply
risk of injury disconnect from power supply
before servicing. For residential use only. See
before servicing. For residential use only. See
instructions for wiring diagram.
instructions for wiring diagram.
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Afg pro-3.0

Table of Contents