IDW G-10F Instruction Manual

IDW G-10F Instruction Manual

Upright cooler g-series

Advertisement

G-10f/GCG-10f
UPRIGHT COOLER
Manual is for the following models:
G-10F, G-10-F33EB
GCG-10F, GCG-10-F33EB
GCG-10F2, GCG-10-F233EB
G-10-F33EB-HC, GCG-10-F33EB-HC
GCG-10-F233EB-HC
Instruction Manual

Advertisement

Table of Contents
loading

Summary of Contents for IDW G-10F

  • Page 1 G-10f/GCG-10f UPRIGHT COOLER Manual is for the following models: G-10F, G-10-F33EB GCG-10F, GCG-10-F33EB GCG-10F2, GCG-10-F233EB G-10-F33EB-HC, GCG-10-F33EB-HC GCG-10-F233EB-HC Instruction Manual...
  • Page 2 Manual is for the following models: G-10F G-10-F33EB GCG-10F GCG-10-F33EB GCG-10F2 GCG-10-F233EB G-10-F33EB-HC GCG-10-F33EB-HC GCG-10-F233EB-HC Instruction Manual G-10f GCG-10f...
  • Page 3: Table Of Contents

    Reversible Door Exchange ..........11 Replacing the Fuse ............13 Troubleshooting ..............14 After-Sales Service ............. 14 G-10f Circuit Diagram ............15 G-10f Electrical Wiring Diagram ......... 16 GCG-10f Circuit Diagram ............ 17 GCG-10f Electrical Wiring Diagram ........18 Innovative DisplayWorks...
  • Page 4: Parts & Identification

    Instruction Manual...
  • Page 5: Safety Precautions

    G-10f/GCG-10f SAFETY PRECAUTIONS When using this appliance, always follow the basic safety precautions: 1. Read the entire User’s Manual before operating this appliance. 2. Use this appliance only for its intended purpose as described in this User’s Manual. 3. This cooler must be properly installed in accordance with the installation instructions before being used. See grounding instructions on page 6.
  • Page 6: Features

    Instruction Manual FEATURES • Designed with an elegant shape and quick refrigeration speed, this commercial-grade product is an ideal choice for shopping malls, supermarkets, hotels, etc. • Transparent glass doors are built with hollow, toughened glass that provides a high level of heat insulation. Clear doors allow for high product visibility.
  • Page 7: Preparation Before Operation

    Leveling • Set unit in its final location, making certain there is adequate ventilation in the room. WARNING: Warranty is void if ventilation is insufficient. • Proper leveling of the G-10f/GCG-10f cooler is critical to it operating correctly. Condensation removal and door operation will be affected by leveling. < The cooler should be leveled front to back and side to side with a level. • Ensure that drain hose or hoses are positioned in the pan.
  • Page 8: Replacing The Interior Light

    Instruction Manual REPLACING THE INTERIOR LIGHT Press two sides of plastic cover by the fingers and remove it. Disconnect the lights. Unscrew (3) screws using a Phillip’s screwdriver. Remove LED light strand. To install LED lights follow the above directions in reverse order.
  • Page 9: Replacing The Door Led Lights

    G-10f/GCG-10f REPLACING THE DOOR LED LIGHTS Unplug the cooler. Disconnect top Remove light strand. plastic cover. Disconnect Unscrew light strand. middle light strand. Remove entire light strand. To install LED lights follow the above instructions in reverse order. Notes: If there are any malfunctions with the main control panel of LED lights, please contact a professional for replacement. SETTING UP SPACER & POWER CORD HOLDERS...
  • Page 10: Startup, Operation & Temperature Adjustment

    Lit Door “Logo” Switch Temperature Adjustment Operation • For GCG-10f • G-10f/GCG-10f performance testing coolers only. position of the thermostat is around 4-6. The light switch located at the bottom • Component shown at the left left hand side on the rear of the...
  • Page 11: Condenser Maintenance

    G-10f/GCG-10f CONDENSER MAINTENANCE It is essential to keep the condenser coils clean and free of dust and debris at all times. It is required to periodically clean the condenser coils with a soft bristle brush or vacuum-cleaner to properly maintain the refrigeration system. Failure to clean the condenser at regular intervals may cause failure of the refrigeration system and could void the warranty.
  • Page 12: Reversible Door Exchange

    Instruction Manual DOOR REVERSAL (For G-10f Coolers Only) Delete clause 1 in the left and adjust the rest clause Seiral No and content as below: 1 Remove the front grill, disconnect the terminals and then hide reversible   d oor   e xchange  ...
  • Page 13 7. Remove the hinge axis from the right bottom hinge, inert it into the left bottom hinge. DOOR REVERSAL Cont. (For G-10f Coolers Only) 8.Remove door limit from right hinge into corresponding holes on left hinge  ...
  • Page 14: Replacing The Fuse

    REPLACING THE FUSE Instruction Manual Add the first clause REPLACING THE FUSE REPLACING THE FUSE Unplug the cooler. Remove the screws from the back grill, and then remove it. Open the cover of the fuse block, as shown in the image to the left. Unscrew the fuse box, then replace the bad fuse. After repair, re-install all parts reversing steps 1-5.
  • Page 15: Troubleshooting

    G-10f/GCG-10f TROUBLESHOOTING The following are not Malfunctions: Issues Solutions Liquid fl owing noise within cooler This liquid is the sound of the cooling agent fl owing through the pipes. Refrigeration system is shutdown for This refrigerator has a strong level of heat preservation and can main- longer periods of time while temperature tain a relatively ambient temperature.
  • Page 16: G-10F Circuit Diagram

    Instruction Manual G-10f CIRCUIT DIAGRAM A: Electric leakage protector E: Evaporator Fan J: Overload for compressor B: Power supply for LED lights F: Fuse K: Compressor C: On/Off switch for interior and door side light G: Socket L: Compressor starting capacitor...
  • Page 17: G-10F Electrical Wiring Diagram

    G-10f/GCG-10f G-10f ELECTRICAL WIRING DIAGRAM SOCKET AC 125V 3A FUSE EVAPORATOR FAN CONDENSER UNIT TEMPERATURE CONTROL SWITCHING POWER SUPPLY DOOR SIDE LED LIGHT INTERIOR INNER TOP LED LIGHT LIGHT SWITCH START CAPACITY CONDENSER FAN CONTROL UNIT RELAY GROUND TO SOCKET...
  • Page 18: Gcg-10F Circuit Diagram

    Instruction Manual GCG-10f CIRCUIT DIAGRAM D1 D2 D3 A: Electric leakage protector D3: Door LED Logo Light B: Power supply for LED lights E: Evaporator fan C1: On/Off switch for Interior light F: Fuse C2: On/Off switch for lit door logo light G: Socket D1: Interior top LED light H: Thermostat...
  • Page 19: Gcg-10F Electrical Wiring Diagram

    G-10f/GCG-10f GCG-10f ELECTRICAL WIRING DIAGRAM Innovative DisplayWorks...