Belt Replacement
Replacing the blower drive belts:
Tools required: Phillips driver, 3/4" wrench (replacement belt part # 460693)
Remove 2 inspection doors on the right side of the unit using a Phillips drive.
Using a ¾" wrench, push down on the tensioner pulley to remove tension from the belts
Remove outer belt first then inner belt
Feed new belts through the belt chanel from the engine side, ensure they are in the proper
pully grooves
Using a 3/4" wrench, push down on the tensioner pulley
Install inner belt on the tensioner then the outer,
Release tension
Install all 2 inspection doors