AVP Configuration

The AVP will receive RS-232 commands without any setup required. However if you chose the AVP
can be set up to ignore the Checksum (CRC) at the end of the command string. By setting the AVP to
ignore the CRC, it will not send out an acknowledgement to the control system.
NOTE: The command list contained in this document shows the complete string for the command
with the correct CRC included. These strings listed in this document should be in whole used even if
the CRC is turned off.
Setting the AVP to ignore CRC
1. Press and HOLD the recall button on the front of the AVP until the MENU appears on the monitor
and the AVP Display reads OSD ACTIVE
2. Before pressing and other buttons Press and Release the SUB button on the AVP followed by the
MASTER button. These buttons must be pressed within 2 seconds of each other
3. A Technical Menu will appear on the monitor. Using the VOLUME control scroll down to CRC.
4. Press the MUTE button on the front of the AVP to select CRC. Use the volume control to change
the setting to OFF.
5. Press MUTE on the front panel to save the change.
6. Press and Release recall until MENUs are exited.

RS-232 Format

The control device must be set to the following settings to communicate with the AVP.
Baud rate
Start bit
Data bits
Stop bit.
Parity
AVP RS-232 Quick Guide
9600
One
Eight
One
None