Additional Functions Max-Power / Zero-Power - ZF ERM Operating Instructions Manual

Electronic control unit
Table of Contents

Advertisement

Electronic control unit ERM
Operating modes
3.6 Additonal functions max-power / zero-power
(I
/ I
)
max
min
Clutch power flow can be influenced irrespective of
operating mode. Zero or max. power for ERM possible
(depends on size of unit connected). Optional limitation of
max. power by MobiDig 200 program.
Application / Use
• Max-power e.g. for emergency stop
• Zero-power e.g. for start-up
Activation of additional functions
Jumper on ERM board must be in Pos. 2. Pos. 1 must not
be connected!
(cf. 1.4 Jumper position).
• Input for max-power function: Pin 15
• Input for min-power function: Pin 14
• Ground: Pin 1 or 2
Each function remains active as long a signal is present on
input (low level, cf. 1.1 Technical data).