Electronic control unit ERM
NOTE
The electronic control unit does not require the potentiometer to
fulfill any particular requirements. However, mechanical require-
ments regarding installation need to be considered.
Recommendations for potentiometer:
Resistance value:
1 kΩ - 47 kΩ
Type:
magnetoresistive potentiometer, for voltage
input nom. value also wire potentiometer
can be used.
Jumper-Position:
Appropriate function is activated by inserting a jumper.
as supplied: standard functions,
tear recognition, friction compensation
1
terminal 14: current zero function;
2
terminal 15; current max. function
3
terminal 8: Ø actual 0 - 5 V, instead of 0 - 10 V
NOTE
Pos. 1 and 2 must never be connected simultaneously.
6057 758 101 - 2005-02