Circuit Board Configuration - ZF ERM Operating Instructions Manual

Electronic control unit
Table of Contents

Advertisement

Technical Data

1.3 Circuit board configuration

Designation
LED (1)
"Power"
LED (2)
"Feedb."
LED (3)
"Ø-Contr."
Connection for
diagnostic unit
Jumper
Fuse
DIL switches
Program memory
Data memory
Terminal strip
6057 758 101 - 2005-02
Function
Supply voltage is applied and ERM program is ready.
Closed-loop control operating mode, i.e. DIL switch position 5 and 6 = "1".
• Ø sensing operation, DIL switch position 5 = "1" and 6 = "0" or
• Ø calculation operation, DIL switch position 5 = "0" and 6 = "1".
• LED "Ø-Contr." flashes, if the setting procedure has not been carried
out in the operating mode Ø calculation or Ø sensing.
Diagnostic connector for ZF MOBiDIG tester
K-cable, acc. to ISO 9141
For function selection. e.g. feed rate interruption, emergency brake
Fine-wire fuse 4 A, medium time-lag fuse
Setting of various operating modes and unit sizes
Includes microprocessor operating program
Contains operating parameters
18-pin
Electronic control unit ERM