Troubleshooting; Technical Specifications - Evolite MOVING BEAM 2R MkII User Manual

Table of Contents

Advertisement

Available languages

Available languages

o Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:
The fixture does not work, no light
o
Check the connection of power and main fuse.
o
Measure the mains voltage on the main connector.
Not responding to DMX controller
o
DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
o
If the DMX LED is on and no response to the channel, check the address settings and
o
If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the fixture or the previous
one.
o
Try to use another DMX controller.
o
Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to
DMX interface circuit.
Some fixtures don't respond to the easy controller
o
You may have a break in the DMX cabling.
o
Check the LED for the response of the master/ slave mode signal.
No response to the sound
o
Make sure the fixture does not receive DMX signal.
o
Check microphone to see if it is good by tapping the microphone.
No light out
o
PLease check if « shutter » is OPEN ( Channel 6 @ 255)
o
Please check if LAMP is « ON »
o
Please check if Channel 7 is "100%" ( Value 255)

Technical Specifications

Model
Lamp
Voltage
Power consumption:
Outside size and N.W.:
Packing size and weight
MOVING BEAM 2R MkII Manual Ver. 1.00
Moving beam 2R MkII
2R lamp 132W
230v 50Hz
300W
430 x 250 x 330 mm / 11.4kg
560 x 340 x 450 cm/ 15kg
DMX polarity.