INSTALLATION Continued

Electrical Connections

Before attempting the electrical connection, the rating
plate should be checked to ensure that the unit's electrical
characteristics and the supply electrical characteristics agree.
Installation of the wiring must be made in accordance with
U.L. 197 Commercial Electric cooking Appliance Standards,
Local and/or National electrical Code, ANSI/NFPA 70-1990.
1. Switch panel size
2. Overload protection
3. Wire type
4. Wire size
5. Temperature limitations of the wires
6. Method of connection (Cable, Conduit, etc)
The service line will enter through the rear of the unit and is
to be connected to the terminal block (see diagram left). The
terminal block is accessed by removing the lower front cover.
Removal of the body side is not necessary.
Input voltage and phasing must match the units voltage
and phasing. Wiring diagram is attached to the main back of
each oven. Visually check all electrical connections. Energize
electric service to units.
The oven is wired per original factory order. If it is necessary
to change to single-phase or three-phase, please refer to kit
part number 4533009.
Service and unit voltage must agree.