Location

Ventilation

Power Supply

6

Locating the Cabinet

When positioning the cabinet, avoid direct sunlight and warm draughts etc,
and areas where the refrigeration unit could be exposed to water or
moisture. The cabinet must NOT be situated where it is affected by warm or
hot air from adjacent equipment, as this will compromise the airflow and
performance of the cabinet. This chiller is designed to operate within a
specific climatic class environment (see cabinet rating label for climate class
number).
Climate Classes
Climate Class Ambient Temperature
3
4
5
The cabinet must be positioned on a level surface for the doors to shut and
seal correctly, and to prevent the condensate tray from overflowing.
Adequate allowance should be made for door and/or drawer opening.
Sandwich and Pizza cabinets have pan openings with hinged pan covers on
the top of the cabinet. Maximum air movement around the opening area of
the cabinet must not exceed 0.3 m/s. Excessive air movement will cause
failure of the air curtain above the pans and excessive temperature rise.
When installing the cabinet
Ensure all packaging is removed from the cabinet.
Avoid direct sunlight and warm draughts etc.
Allow adequate space for the door/s and/or drawer/s to open fully.
Ensure the cabinet is positioned on a level surface so the door/s shut
and seal correctly and to prevent the condensate tray from overflowing.
Air movement above Sandwich and Pizza cabinets must not exceed 0.3
m/s.
It is critical that the hot refrigeration exhaust air is not restricted and that it
can easily flow out and away from the front of the cabinet. Never store
cardboard cartons or other items in front of or on top of the refrigeration unit.
The ventilation slots on the refrigeration unit front cover and at the rear of
the cabinet must be kept clear at all times. Normal operating conditions
should not exceed the operating temperature range (see page 4).
Horizontal cabinets (undercounter, sandwich and pizza)
Ensure there is always at least a 150mm gap around the back and the
refrigeration unit side of the cabinet.
Vertical cabinets
Ensure there is always at least a 150mm gap around the back and sides of
the cabinet, and at least 500mm above the cabinet.
The cabinet is supplied with a flexible power cord and plug which exits the
rear of the cabinet.
Before final positioning of the cabinet, pull the power cord out from the rear
compartment and connect to the power supply. For convenience, any
surplus cord length may be left inside the cabinet compartment.
Do NOT overload the power supply. See the rating label inside
the cabinet for power supply and current draw.
Relative Humidity (RH)
25°C
30°C
40°C
WARNING
60%
55%
40%
Installation
User Manual