SKOPE Centaur Series
18

Troubleshooting

Complaint
Possible Cause
1. Cabinet not
• Loss of power supply.
operating and
no controller
display:
2. Power
• Unit operating too hot.
consumption
is higher than
expected:
• Cabinet doors are opened
excessively.
3. Product is too
• Restricted cabinet airflow.
warm and
spoiling:
• Temperature setpoint is too
warm.
• Food preparation covers
raised for extended periods.
4. Warm cabinet
• Blocked condenser.
temperatures
and/or
• Poor refrigeration unit
compressor
ventilation.
operating for
long periods
(more than 1
hour):
Repair
• Check that the cabinet
power switch is turned on
(see page 10).
• Check mains power supply.
• Clean condenser. Ensure
the cabinet is installed with
good ventilation around the
refrigeration unit.
• Keep door/s open for
minimum time.
• Ensure product is not
blocking airflow slots and the
product is no closer than
75mm from the cabinet top.
• Adjust setpoint (see
page 13).
• The covers must stay closed
when not in use (see
page 9).
• Clean condenser coil (see
page 16).
• Ensure the cabinet is
installed with good
ventilation around the
refrigeration unit.
Maintenance
User Manual