    Models Undercounter Operating temperature Model Type Part No. Doors range BC070-CB B070CB-1ROOS-E 1 × solid door BC090-C B090-C-1ROOS-E 1 × solid door BC090-CS B090-CS-3ROOS-E 3 × drawers 1°C to 4°C up to 38°C ambient BC120-C B120-C-2RROS-E 2 × solid door Chiller BC180-C B180-C--3RRRS-E...
  • Page 5: Installation

    SKOPE Centaur Series Installation Safety First Always observe safety precautions when using any electrical appliance. Read these instructions carefully and retain them for future reference. When the appliance is used by or near young children or infirm persons,  close supervision is necessary, especially to ensure children do not play with it.
  • Page 6: Locating The Cabinet

    SKOPE Centaur Series Locating the Cabinet Location When positioning the cabinet, avoid direct sunlight and warm draughts etc, and areas where the refrigeration unit could be exposed to water or moisture. The cabinet must NOT be situated where it is affected by warm or hot air from adjacent equipment, as this will compromise the airflow and performance of the cabinet.
  • Page 7: Positioning The Cabinet

    SKOPE Centaur Series Positioning the Cabinet The cabinet is fitted with a set of four swivel castors, and is supplied with a set of four adjustable height legs, which can be fitted in place of the castors depending on specific height and manoeuvrability requirements. The legs or castors should be fitted to the base of the cabinet before final positioning.
  • Page 8: Shelving

    SKOPE Centaur Series Shelving The cabinet is supplied with shelves and shelf support brackets which can be positioned at different heights to suit various products. To fit the shelves 1. Unpack the shelving items from inside the cabinet. 2. Establish the desired position for each of the shelves, based on the height of the product intended to go on each shelf.
  • Page 9: Gastronorm Containers

    SKOPE Centaur Series Gastronorm Containers Sandwich and Sandwich and Pizza cabinets are supplied with gastronorm food preperation Pizza Cabinets containers which fit into openings on top of the cabinet, and hinged covers. Refer to the tables below for standard container and hinged cover quantities: Sandwich cabinet Model Doors...
  • Page 10: Operation

    SKOPE Centaur Series Operation Automatic Start-Up IMPORTANT If the cabinet has been on its back, leave for 30 minutes before running. Connect the cabinet to the mains power supply and check operation of the refrigeration unit and electronic controller. Ensure the cabinet power switch is turned on.
  • Page 11: Electronic Controller

    SKOPE Centaur Series Electronic Controller Introduction Depending on the model, the cabinet will be fitted with a CAREL Easy electronic controller or a CAREL ir33 electronic controller (refer to faceplate below to identify the type of electronic controller. The electronic controller is visible through a cut-out in the front panel. It controls and displays the cabinet interior temperature and signals temperature alarms.
  • Page 12 SKOPE Centaur Series CAREL ir33 electronic controller CAREL ir33 electronic controller faceplate Item Icon Function Mute / program: Mutes the audible alarm (buzzer) and deactivates the alarm relay. To initiate program sets, press for 5 seconds. Up: To scroll settings up (in program mode). Set point: If pressed for more than 2 seconds displays and / or enables changing the temperature setpoint.
  • Page 13: Stand-By Mode

    SKOPE Centaur Series Stand-by Only applicable on the CAREL Easy electronic controller. Press and hold the Mode stand-by button for three seconds to turn stand-by mode on or off. When stand-by mode is on, the controller display will alternate between the cabinet temperature and Of, and the compressor, fans and alarms are disabled.
  • Page 14 SKOPE Centaur Series CAREL ir33 messages and alarms Code Display Alarm Action 1. Check the cabinet product loading to ensure Product HIGH ventilation slots are not blocked, and that temperature alarm product does not overhang the shelves. (auto reset) Flashing Ensure the doors are closed.
  • Page 15: Maintenance

    SKOPE Centaur Series Maintenance Cleaning To ensure the chiller continues to run efficiently and reliably, the following maintenance should be carried out: Cleaning Cabinet Keep the interior and exterior of the cabinet clean by regular wiping with a damp cloth. The food preparation pans and air diffuser panels can be easily lifted from the cabinet for cleaning (Sandwich and Pizza cabinets...
  • Page 16 SKOPE Centaur Series To clean the condenser coil on horizontal cabinets 1. Isolate the cabinet from the power supply by unplugging it from the wall. 2. Open the unit front cover (usually located on the LH side of cabinet) to gain access to the condenser filter and coil.
  • Page 17: Lighting

    SKOPE Centaur Series Lighting Cabinet Depending on the model, the cabinet may be fitted with one of the light Interior Lights variations shown in the table below. Follow the relevant procedure further below to replace the light. Note: Some models are not fitted with interior lights. Centaur light variations Light type 25W bulb (OSRAM PYGMY CL25E14)
  • Page 18: Troubleshooting

    SKOPE Centaur Series Troubleshooting Complaint Possible Cause Repair 1. Cabinet not • Loss of power supply. • Check that the cabinet operating and power switch is turned on no controller (see page 10). display: • Check mains power supply. 2. Power •...
  • Page 19 SKOPE Industries Limited NEW ZEALAND CONTACT Head Office PO Box 1091, Christchurch New Zealand Freephone: 0800 947 5673 Fax: (03) 983 3896 E-mail: enquiry@skope.co.nz Website: www.skope.co.nz AUSTRALIAN CONTACT A.B.N. 73 374 418 306 PO Box 7543, Baulkham Hills B.C. NSW 2153, Australia Freephone: 1800 121 535 Fax: 1800 121 533 E-mail: enquiry@skope.com.au...