8.1.6) Changing the gas springs

Replace the gas springs when required as follows:
On both sites loosen screws (A) with an 8 mm Allen
key and screws (B) with a 6 mm Allen key then remove
the casing (Ref. to Fig. 27).
Unlock the arm in order to extend the springs (Ref .
to Fig. 28).
Use a fi nger to release the retaining rings located at
the ends of the spring and simultaneously detach it
from the pins (Ref. to Fig. 29).
Place the new spring on the same pins, pressing it
with force until it is inserted, respecting its original
orientation.
Reposition the retaining rings.
Repeat this process for both springs.
Replace the casing and fasten it by tightening the
screws.
FIG. 28

8.2) Routine maintenance of the engine

Checks and periodic servicing are indispensable to ensure smooth engine operation.
Refer to the "HONDA owner's manual" supplied with the machine for the following operations:
Oil change (fi rst change after 20 hours of work)
Air fi lter assistance (see double-element type)
Cleaning sediment from sump
Spark plug cleaning; recommended plugs BPR6ES (NGK) or W20EPR-U (DENSE)
Minimum carburettor setting

8.3) Long periods of inactivity

Store the machine in a dry environment and adequately protect it against accidental damage and contamination.
For information on the engine, refer to the "HONDA owner's manual".