8.1.3) Topping up the oil in the hydraulic pump
FIG. 23
FIG. 24
FIG. 25
Periodically check the oil level in the hydraulic pump
tank.
If the level is low, top it up:
Remove and lift the cap, check that the level of oil
is between the two notches on the dipstick, if it is
lower add the quantity of oil necessary (Ref. to Fig. 24).
After topping up, tightly screw the cap back on.
Always use clean recommended oil, see § 1.
Do not use old or recycled oil.
Do not use hydraulic brake fl uid.
8.1.4) Replacing the hydraulic pump oil fi lter
Detach connector (C), unscrew ring nut (G) paying
attention to the seal inside it and remove solenoid
coil (B) (Ref. to Fig. 23).
Use a 16 mm spanner to unscrew the nut on the
fi lter and replace the fi lter (Ref. to Fig. 25).
Once this has been completed relocate the solenoid
coil of the electro-valve, its connector and ring nut.
8.1.5) Adjusting the worklights
Loosen the nut on the worklight fastening pin (Ref.
to Fig. 26).
Turn the worklight to the desired position then
retighten the nut.
FIG. 26