Toshiba RAV-GM301ATP-E Service Manual page 81

Hide thumbs Also See for RAV-GM301ATP-E:
Table of Contents

Advertisement

No.
Part name
Compressor
1) Perform works of items 1 of 1 and 2 ,
7
3
2) Discharge refrigerant gas.
3) Remove the partition plate.
(ST1T Ø4 × 10L, 3 pcs.)
4) Remove the terminal covers of the
compressor, and disconnect lead wires
of the compressor and the compressor
thermo assembly from the terminal.
5) Take off the soundproof plate.
6) Remove pipes connected to the
compressor with a burner.
Pay attention to that flame does not
involve 4-way valve or PMV. (If doing
so, a malfunction may be caused.)
7) Take off the fixing screws of the bottom
plate and heat exchanger.
(ST1T Ø4 × 10L)
8) Take off the fixing screws of the plate
fix valve to the bottom plate.
(ST1T Ø4 × 10L, 2 pcs.)
9) Pull upward he refrigerating cycle.
10) Take off nut fixing the compressor to
the bottom place.
When reconnecting the lead wires to
the compressor terminals after
replacement of the compressor, be
sure to caulk the Faston terminal
without loosening.
Reactor
1) Perform works of item 1 of 1 , 2
8
and 3 .
2) Remove partition plate
(ST1T Ø4 × 10L, 3 pcs.)
3) Take off screw attached to reactor
(ST1T Ø4 × 10L, 5 pcs.)
Procedure
,
5
.
CAUTION
CAUTION
Remove
(Discharge pipe)
– 81 –
FILE NO. SVM-18042
Remarks
Partition plate
Compressor
lead
Screw
Remove
(Suction pipe)
Screw
Plate fix Valve