To secure the fire using the preferred cable method, proceed as follows :-
a)
Mark out and drill 3 off No 14 6mm holes in the rear face of the fire
opening in the positions as shown on fig. 10 below.
Fig. 10
500mm
b)
Fit the wall plugs provided and screw the fixing eyes securely into the
rear of the fire opening.
c)
Uncoil the two fire fixing cables and thread one end of the each of the
cables through the rear of the fire box, and through each fixing eye at
the top. Thread both cables through the fixing eye at the bottom.
d)
Thread the cables through the rear of the firebox, insert the flue pipes
through the hole in the rear of the wall and offer the firebox up to the
fireplace.
e)
Thread the cables through the bracket which is situated on the base.
f)
Thread a tensioning screw over both of the cables and ensure that the
tensioning nut is screwed fully up against the hexagon shoulder of the
tensioning screw (this provides maximum travel for the tensioning nut.
g)
Fit a screwed nipple on to each of the cables and pull hand tight up
against the tensioning screw, then secure each nipple with a flat bladed
screwdriver. See fig 11 overpage.
250mm
13