2 Description
2.3
3BSE023881R0101 en Rev H
Material
Accuracy
Accuracy class
Linearity deviation
Repeatability error
Hysteresis
Compensated temperature range
Zero point drift
Sensitivity drift
Working temperature range
Zero point drift
Sensitivity drift
Storage temperature range
1) Definitions of directions designations "
F
are given in Section
2.5.1 Coordinate
A
2) F
and F
are allowed at the same time.
max
Vmax
3) Max. permitted load for the load cell is 10 × F
overload capacity for the total installation may be limited by
the screws.

Definitions

Nominal load
Nominal load, F
, is the maximum load in the measurement direction for which the load cell is
nom
dimensioned to measure within the specified accuracy class. The load cell is calibrated up to F
Sensitivity
Sensitivity is defined as the difference in output values between nominal load and zero load.
C/CD/CE
Stainless steel SIS 2387 DIN X4CrNiMo 165
C/CD/CE
± 0,5
< ± 0,3
< ± 0,05
<0,2
+20 - +80
50
100
-10 - +90
100
200
-40 - +90
"and "
" in F
and
V
A
V
System.
. The
nom
h= Building Height
%
°C
ppm/K
°C
ppm/K
°C
h
Pressductor
System
.
nom
11