TROUBLESHOOTING
Door will not unlock.
LED does not illuminate.
Lock does not release
upon detection, but LED
illuminates.
Size of detection field does
not meet requirements
TECHNICAL SPECIFICATIONS
Technology:
Mounting Height (variable):
Mounting Angles:
Power Supply:
Current Consumption:
Contact Rating (output relay):
Optical Characteristics:
Warm-up TIme:
Response TIme:
Relay Hold Time:
Fly:
Fly ERT:
Operating Temperature:
Immunity:
Cable:
Weight:
Sensor Dimensions:
Housing Color:
BEA Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments or the sensor/device; therefore, BEA Inc. does not
guarantee any use of the sensor outside its intended purpose.
BEA Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-trained for
the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor system installation
and/or device is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the system should be performed and documented per the manufacturers recommendations, or
industry guidelines. Examples of compliance may apply to ANSI 156.10, ANSI 156.19, ANSI/DASMA 102, ANSI/DASMA 107, UL294, International Building Code.
General Tech Questions: Tech_Services@beainc.com | Tech Docs: www.BEAinc.com
Page 4 of 4
Page 4 of 4
Sensor power is off.
Incorrect relay output.
Incorrect wiring.
Incorrect cut-out of masking lens.
Passive infrared with microprocessor
10' max. (recommended 6'6" – 8'0")
0 – 180°
12 – 24 VAC ±10% (50/60Hz)
12 – 24 VDC -10% / +30%
< 10 mA (20 mA if the relay output is activated)
1 A / 75 VDC OR 50 VAC potential-free contact NO/NC
Passive infrared with 4 elements
15 Fresnel lenses with full independent making possibilites
10 seconds
Max. 200 microseconds
0.5 or 2 seconds
15 or 30 seconds
-22 − 140 °F (-30 − 55 °C)
Immune to electrical and radio frequency interference
9' four-conductor cable with 5-pin connector
1.4 oz. (40 g)
4" (L) x 1" (H) x 1.8" (W)
100 mm (L) x 25 mm (H) x 45 mm (W)
Black
Specifications are subject to change without prior notice.
All values measured in specific conditions.
BEA INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462
Check power supply.
Check supplied voltage.
Change #2 DIP switch position.
Verify correct wiring.
Replace sensor.
Cut a new lens to meet the required
detection field size.
75.0152.04 FLY 20180523
75.0152.04 FLY 20180523