Summary of Contents for MICROWELL HP 1100 COMPACT PREMIUM
Page 1
HEAT PUMP for swimming pool water Installation and user manual heating & cooling HP 1100 COMPACT PREMIUM HP 1500 COMPACT PREMIUM Version: 03/2016...
V e r s i o n : 0 1 / 2 0 1 8 P a g e 2 / 2 8 Thank you for purchasing Microwell swimming pool heat pump. Before you use this device, it is necessary to carefully read the entire Installation and user manual.
Page 3
HP1100/1500COMPACT PREMIUM I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 3 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Description of the LCD panel ....................
HP1100/1500COMPACT PREMIUM I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 5 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Ideal water temperature for external pools is considered at levels from 27°...
HP1100/1500COMPACT PREMIUM I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 9 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 It is also advised to keep the water hardness on the lower limit of the optimal range, i.e.
I n s t a l l a t i o n a n d u s e r m a n u a l HP1100/1500 COMPACT PREMIUM V e r s i o n : 0 1 / 2 0 1 8 P a g e 1 0 / 2 8 Security and control systems In order to ensure long term reliability and fully automatic operations of the heat pump, the pump is...
HP1100/1500COMPACT PREMIUM I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 1 1 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Block wiring diagram of the PCB board Sensors 4-way...
HP1100/1500COMPACT PREMIUM I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 1 3 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Connection to water filtration circuit The heat pump must be connected to water circuit (filtration circuit) of the swimming pool in order to provide desired heating/cooling performance.
I n s t a l l a t i o n a n d u s e r m a n u a l HP1100/1500 COMPACT PREMIUM V e r s i o n : 0 1 / 2 0 1 8 P a g e 1 4 / 2 8 Needed components for connection to water circuit It is advised to use hose nut with external thread PN16 50 x 6/4”...
Page 15
HP1100/1500COMPACT PREMIUM I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 1 5 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Scheme: Connection of the compact heat pump into the water filtration circuit of the swimming pool Note: The manufacturer supplies the heat pump only.
I n s t a l l a t i o n a n d u s e r m a n u a l HP1100/1500 COMPACT PREMIUM V e r s i o n : 0 1 / 2 0 1 8 P a g e 1 6 / 2 8 Electrical connection I M P ORTANT: The electric connection of the heat pump can only be...
28°C Control of the circulation pump Microwell swimming pool heat pump is able to control the circulation pump. In principle should the heat pump be in need for heating/cooling it will automatically turn the circulation pump on. In order to enable this control, the circulation pump must be connected to the heat pump electrically (please refer to section 3.6 Block wiring diagram of the PCB board...
I n s t a l l a t i o n a n d u s e r m a n u a l HP1100/1500 COMPACT PREMIUM V e r s i o n : 0 1 / 2 0 1 8 P a g e 2 0 / 2 8 General heat pump control After the installation, the heat pump is to be controlled by digital display only.
HP1100/1500COMPACT PREMIUM I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 2 1 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Heat pump operational modes Auto mode ...
I n s t a l l a t i o n a n d u s e r m a n u a l HP1100/1500 COMPACT PREMIUM V e r s i o n : 0 1 / 2 0 1 8 P a g e 2 2 / 2 8 Automatic turning off You can use this function when you would like your heat pump turned off after some time period.
HP1100/1500COMPACT PREMIUM I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 2 5 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Condensate tray defrost Condensate tray defrost ensures protection of the tray against frost.
I n s t a l l a t i o n a n d u s e r m a n u a l HP1100/1500 COMPACT PREMIUM V e r s i o n : 0 1 / 2 0 1 8 P a g e 2 6 / 2 8 Defrosting in section 3.5 Security and control systems...
HP1100/1500COMPACT PREMIUM I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 2 7 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Position 2: Heat pump bent Position 1: Heat pump in over for water bleeding.
I n s t a l l a t i o n a n d u s e r m a n u a l HP1100/1500 COMPACT PREMIUM V e r s i o n : 0 1 / 2 0 1 8 P a g e 2 8 / 2 8 Failure reports Please find below table containing list of failure reports with their explanation and suggested solution.
Page 29
HP1100/1500COMPACT PREMIUM I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 2 9 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 condensing unit.
HP1100/1500COMPACT PREMIUM I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 3 1 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 on refrigerant circuit (leakage, restriction, not enough refrigerant, etc.) If this error occurrs repeteadly, please...
Installation and user manual is excluded from warranty coverage. Distributed by: Manufacturer: MICROWELL, spol. s r.o. SNP 2018/42, 927 01 Sala, Slovakia tel.: +421/31/702 0540 fax: +421/31/702 0542 e-mail: microwell@microwell.sk...
Need help?
Do you have a question about the HP 1100 COMPACT PREMIUM and is the answer not in the manual?
Questions and answers