  • Page 1 HEAT PUMP for swimming pool water Installation and user manual heating & cooling HP 1000 GREEN HP 1400 GREEN HP 1700 GREEN COMPACT & SPLIT Version: 01/2023 REA DY...
  • Page 2: Table Of Contents

    Thank you for purchasing Microwell swimming pool heat pump. Before you use this device, it is necessary to carefully read the entire Installation and user manual. It is not allowed to commence the heat pump installation or operation unless full content of this Installation and user manual is understood and acknowledged.
  • Page 3: Introduction

    H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l 1.
  • Page 4: Package Checking

    Ideal water temperature for external pools is considered at levels from 27° to 32°C. This may change based on particular demands of the user. When setting the desired air temperature higher than 32°C please review the material characteristics of your pool parts. High water temperature can damage these materials and contribute to creation of algea.
  • Page 5: Electrical Safety

    H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l your country that regulate the installation and usage of this device.
  • Page 6 • Prevent the children from injury or harm caused by any manipulation with the unit, its parts or its packaging. Small parts like screws may be swallowed and cause harm to health. • Do not leave the children in the swimming pool / at the swimming pool unattended. The positioning of the heat pump must be in accordance with the STN 33 2000-7-702 standard, i.e.
  • Page 7: Handling Precautions

    H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l Vacuumize completely before welding.
  • Page 8 may seem to work well at start but small damage can make the unit go out-of-order in short time. In such case the unit must be inspected and approved for further use by your reseller. Please notify your reseller or distributor if directly after installation you suspect that unit is not •...
  • Page 9: Technical Specification

    H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l 3.
  • Page 10: Heat Pump Dimensions

    Should you have different values of pH, chlorine or salt please try to apply appropriate agents or contact your swimming pool builder to resolve the situation. Above mentioned values are recommended for pools in general. It is also advised to keep the water hardness on the lower limit of the optimal range, i.e. closely above 8 °N. Heat pump dimensions Note: The illustrations and descriptions found in this Installation and user manual are not...
  • Page 11: Explosion View

    H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l Explosion view Top cover Fixed plate 2...
  • Page 12: Installation Instructions

    Installation instructions WARNING: Installation must be carried out by a qualified engineer. This section is provided for information purpose only and must be checked and adapted if necessary according to actual installation condition. a. Pre-Requirements Needed equipment for installation of heat pump: •...
  • Page 13: Electric Wiring Diagram

    H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l Do not put any stuff on or in front of heat pump! c.
  • Page 14: Split Additional Connection

    HP1400 GREEN、HP1700 GREEN Reference for protecting devices and cable specification Power Supply Wires Model Electricity Supply Cable Diameter Specification HP1000 GREEN 3×2.5mm2 AWG 14 HP1400 GREEN 220-240V~/50Hz 3×2.5mm2 AWG 14 HP1700 GREEN 3×4.0mm2 AWG 12 ※ Above data is subject to modification without notice. Note: The above data is adapted to power cord ≤...
  • Page 15: Remote Controller Operation Guidance

    H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l HEAT PUMP Circulation pump connection...
  • Page 16: Key Operating Instruction

    Icon Meaning Icon Meaning WI-FI Timer on Electric heating Timer off Heating mode Smart mode Defrost state(Flash) Powerful mode Automatic mode Silent mode Cooling mode Table 2 Meaning Function Mode key Switch mode and set parameter Up key Manual defrost and set water temp. Turn ON/OFF,lock/unlock and return to main Power key interface...
  • Page 17 H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l Item Operation Way Select Running...
  • Page 18: System Status

    Item Operation Way Within 30S of initial power-on, press " " + " " for 2s to enter the online test function and the unit will run the hardware SOP test program. The Online Test operation specification can be referred to the hardware SOP design Function specification.
  • Page 19: Split - Connection And Installation

    H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l Low voltage protection Inlet water temp.sensor fault Outlet water temp.sensor fault...
  • Page 20: Refrigerant Circuit Connection

    Refrigerant circuit connection Split heat pump requires refrigerant circuit connection in order to operate normally. This is normally done during installation of the pump as the pump comes with separate (not connected) condensing and water units refrigerant-wise originally from the factory. Refrigerant circuit must be sealed. I M P ORTANT: Please note that refrigerant connection can be performed by an authorized person only.
  • Page 21 H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l HP1700 9.53 15.88...
  • Page 22: Flaring Work

    with cable binder or equivalent onto the exterior wall. It is important to make a trap to prevent water from entering into the electro installation of the condensing unit. Trap Trap 3.2 Condensing unit above water unit Syphon Tape the piping and interconnecting cable min.
  • Page 23 H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l Pressure test / Air purging Sometimes bits of air and moisture remains in the refrigerant circuit.
  • Page 24 4. Put service valve caps back at both gas and liquid side service valves and fasten them tight. This completes air purging with a vacuum pump and refrigerant works. Condensing unit Please note that above flaring and refrigerant work must be performed correctly with utmost care. Any non-compliance with above may and will likely lead into heat pump’s malfunction, failure or damage.
  • Page 25: Water Unit Dimensions

    H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l Water unit dimensions ∅140 G3/4"...
  • Page 26: Connection To Pv

    This section is for all users or applications where photovoltaic panels are installed and used as energy source. Your Microwell heat pump is equipped with PV Ready solution enabling you to minimize your energy bill by powering your heat pump from photovoltaic energy source. You have several options how to operate your heat pump: 1.Maximum comfort –...
  • Page 27 If the power keeps on being low, then the heat pump will be turned off. It is save to operate your Microwell heat pump in this way. Please note that even in the case PV panels generate enough power, your heat pump may be off and not working.
  • Page 28: Wi-Fi Settings

    7. Wi-Fi Settings Software Installation ① Method 1: Search ”Smart life” in your APP store ,install “ ”.Click “GET” to install. ② Method 2: Scan the QR code below. For IOS and Android Users Software Startup After installation,click “ ” on your desktop to start up Smart Life.
  • Page 29: Software Registration And Configuration

    H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l Software Registration and Configuration 1.
  • Page 30 2. Account ID+ Password Login ① Existing accounts can be logged in directly, in the following order. ② If you forget your password you can choose to login with your verification code and select "Forget Password": Enter your phone number Get verification code .
  • Page 31 H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l ③...
  • Page 32 Step 2: Turn on the phone's Wi-Fi function and connect to the Wi-Fi hot-spot. The Wi-Fi hot-spot must be able to connect to the Internet normally; Step 3: Open the "smart life" APP, log in into the main interface, click on the top right corner "+" or "add equipment"...
  • Page 33 H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l that the wire controller has selected the EZ mode.
  • Page 34 AP Mode: Press and hold the keys at the same time for 3 seconds to enter " " the distribution network. The " " icon will flash slowly. Step 2&3 Same with EZ Mode above. Step 4 After entering the add device interface, click "EZ Mode" in the upper right corner; Enter the AP mode to add the device interface, confirm that the AP mode has been selected, and click"Confirm indicator slowly blink".
  • Page 35: Software Function Operation

    H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l Enter the mobile phone Wi-Fi connection interface, find the “Smart Life_XXXX”...
  • Page 36 ① Back ② More: You can change device name, select device installation location, check networking status, add Shared users, create device cluster, view device information, and more. ③ Setting temp. adjustment: The circle slides counterclockwise to reduce the temp., but clockwise to increase the temp.. ④...
  • Page 37 H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l Device sharing ...
  • Page 38  The interface of the person to be shared is as follows. The received shared device is displayed. Click it to operate and control the device. Mode settings  Click “ ” on the main interface to switch modes,select what you need.
  • Page 39 H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l Timer setting ...
  • Page 40: Device Removal

    ① Hours ② Minutes ③ Set the repetition ④ Set power ON/OFF ⑤ Save your modification Device Removal Click “ ” on the top right corner of the main interface to enter the device details interface, and click “device removal” to enter EZ mode. Indicator light under“ ”...
  • Page 41 H P 1 0 0 0 / 1 4 0 0 / 1 7 0 0 G r e e n I n s t a l l a t i o n a n d u s e r m a n u a l...
  • Page 42: Maintanance & Warranty

    7. MAINTANANCE & WARRANTY Maintanance “CUT OFF” power supply of the heater before cleaning, examination and repairing 1. In winter season when you don’t swim: a. Cut off power supply to prevent any machine damage. b. Drain water clear of the machine. !!Important: Unscrew the water nozzle of inlet pipe to let the water flow out.