MICROWELL HP 900 Compact Installation And User Manual

MICROWELL HP 900 Compact Installation And User Manual

Heat pump for swimming pool water heating

Advertisement

HEAT
PUMP
for swimming pool
water heating
Installation and user manual
HP 900 COMPACT
&
HP 1200 COMPACT
Version: April 2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HP 900 Compact and is the answer not in the manual?

Questions and answers

Summary of Contents for MICROWELL HP 900 Compact

  • Page 1 HEAT PUMP for swimming pool water heating Installation and user manual HP 900 COMPACT & HP 1200 COMPACT Version: April 2014...
  • Page 2: Table Of Contents

    I n s t a l l a t i o n a n d u s e r m a n u a l CONTENTS 1. Introduction 1.1 How to use the heat pump 1.2 Heat pump operation 1.3 Package checking 2.
  • Page 3: Introduction

    I n s t a l l a t i o n a n d u s e r m a n u a l 1. INTRODUCTION Thank you for purchasing our heat pump. The heat pump is manufactured in accordance with the related strict standards and norms, in order to provide high quality operation and reliability to our customers.
  • Page 4: Safety Measures

    I n s t a l l a t i o n a n d u s e r m a n u a l 2. SAFETY MEASURES WARNING: The product contains electric parts under pressure. Every operation must be performed by a specialised technician. Risk of injury by electric current. a) The positioning of the heat pump must be in accordance with the STN 33 2000-7-702 standard, i.e.
  • Page 5: Product Description And Technical Specification

    I n s t a l l a t i o n a n d u s e r m a n u a l 3. PRODUCT DESCRIPTION AND TECHNICAL SPECIFICATION 3.1 Technical data HP 900 COMPACT HP 1200 COMPACT 25°C/10°C 25°C/20°C...
  • Page 6: Description Of The Basic Parts

    I n s t a l l a t i o n a n d u s e r m a n u a l 3.4 Description of the basic parts Legend: – Protecting grates of the fan (air outlet) –...
  • Page 7: Block Wiring Diagram Of The Pcb Board

    I n s t a l l a t i o n a n d u s e r m a n u a l pressures in the cooling circuit of the heat pump get balanced. Interruption of the power supply during the pause time does not influence the time interval.
  • Page 8: Heat Pump Installation And Connection

    I n s t a l l a t i o n a n d u s e r m a n u a l 4. HEAT PUMP INSTALLATION AND CONNECTION 4.1 Positioning The heat pump is designed for outdoor istallation. It will work well in any kind of outdoor environment, where the following 3 requests are satisfied: 1.
  • Page 9: Heat Pump Installation

    I n s t a l l a t i o n a n d u s e r m a n u a l 4.2 Heat pump installation a) The heat pump is used in conjunction with the filtrating unit, which is one of the swimming pool installation elements.
  • Page 10 10 | I n s t a l l a t i o n a n d u s e r m a n u a l Connection of the compact heat pump into the filtration circuit of the swimming pool Note: The manufacturer supplies only the heat pump.
  • Page 11: Electric Connection

    I n s t a l l a t i o n a n d u s e r m a n u a l | 11 4.3 Electric connection 4.3.1 Connection to the plug adapter I M P ORTANT: The heat pump is supplied with a flexible cord with a fork, for connection to the 230V/50Hz plug adapter.
  • Page 12: Control Unit

    12 | I n s t a l l a t i o n a n d u s e r m a n u a l 5. CONTROL UNIT 5.1 Functions of the control unit with LCD panel Cooling symbol Blinking sun- defrosting LCD display...
  • Page 13: Turning On/Off The Operating / Stand-By Mode And Setting Of The Requested Water Temperature

    I n s t a l l a t i o n a n d u s e r m a n u a l | 13 Figure Meaning Range Manufacturing Setting (YES/NO) setting Setting of the defrosting time period 30 ~150 min.
  • Page 14: Checking Of The Current Values Of Some Parameters

    14 | I n s t a l l a t i o n a n d u s e r m a n u a l By pressing the button, the temperature gets 1°C higher, by pressing the button it gets 1 °C lower.The setting range is 5°C ~ 40°C.
  • Page 15: Timer Setting

    I n s t a l l a t i o n a n d u s e r m a n u a l | 15 5.5 Timer setting (Timer ON, Timer OFF) By the timer function you turn on/off the device automatically. In the STAND-BY mode (OFF) the „on“...
  • Page 16: Water Condensation

    16 | I n s t a l l a t i o n a n d u s e r m a n u a l Completely close the valve No1 and open valves No2 and No3 on the heat pump inlet and outet. Under these conditions, there is a maximum amount of water flowing through the heat pump.
  • Page 17: Simplified Control Diagram

    I n s t a l l a t i o n a n d u s e r m a n u a l | 17 The swimming pool water temperature should not exceed 30 . Too hot water is not ...
  • Page 18: Maintenance And Checking Of The Device

    18 | I n s t a l l a t i o n a n d u s e r m a n u a l 7. MAINTAINANCE AND CHECKING OF THE DEVICE 7.1 Maintainance CAUTION: The device contains electrical parts under pressure. Only a specialised technician can work on the device.
  • Page 19: Warranty Conditions, Service And Spare Parts

    7.3 Warranty conditions, service and spare parts The warranty is applicable to cases described in the warranty certificate. The technical service as well as the spare parts are provided by the manufacturer, MICROWELL, spol. s.r.o. through their service centers. 7.4 Failure reports and their elimination...
  • Page 20 Distributed by: Producer: MICROWELL, spol. s r.o. SNP 2018/42, 927 01 Šaľa, Slovakia tel.: +421/31/702 0540 fax: +421/31/702 0542 e-mail: microwell@microwell.sk w w w . m i c r o w e l l . e u...

Table of Contents