Summary of Contents for MICROWELL HP 2400 COMPACT Premium

  • Page 1 HEAT PUMP for swimming pool water heating & cooling Installation and user manual HP 2400 COMPACT Premium & HP 3000 COMPACT Premium Version: 01/2018 jún 2011...
  • Page 2: Table Of Contents

    V e r s i o n : 0 1 / 2 0 1 8 P a g e 2 / 2 8 Thank you for purchasing Microwell swimming pool heat pump. Before you use this device, it is necessary to carefully read the entire Installation and user manual.
  • Page 3 H P 2 4 0 0 / 3 0 0 0 C o m p a c t I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 3 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Description of the LCD panel ....................
  • Page 4: Introduction

    I n s t a l l a t i o n a n d u s e r m a n u a l H P 2 4 0 0 / 3 0 0 0 C o m p a c t V e r s i o n : 0 1 / 2 0 1 8 P a g e 4 / 2 8 1.
  • Page 5: Package Checking

    H P 2 4 0 0 / 3 0 0 0 C o m p a c t I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 5 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Ideal water temperature for external pools is considered at levels from 27°...
  • Page 6: Safety Measures

    I n s t a l l a t i o n a n d u s e r m a n u a l H P 2 4 0 0 / 3 0 0 0 C o m p a c t V e r s i o n : 0 1 / 2 0 1 8 P a g e 6 / 2 8 2.
  • Page 7: Handling Precautions

    H P 2 4 0 0 / 3 0 0 0 C o m p a c t I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 7 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 swimming pool.
  • Page 8: Technical Specification

    I n s t a l l a t i o n a n d u s e r m a n u a l H P 2 4 0 0 / 3 0 0 0 C o m p a c t V e r s i o n : 0 1 / 2 0 1 8 P a g e 8 / 2 8 3.
  • Page 9: Heat Pump Dimensions

    H P 2 4 0 0 / 3 0 0 0 C o m p a c t I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 9 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Should you have different values of pH, chlorine or salt please try to apply appropriate agents or...
  • Page 10: Security And Control Systems

    I n s t a l l a t i o n a n d u s e r m a n u a l H P 2 4 0 0 / 3 0 0 0 C o m p a c t V e r s i o n : 0 1 / 2 0 1 8 P a g e 1 0 / 2 8 Security and control systems...
  • Page 11: Block Wiring Diagram Of The Pcb Board

    H P 2 4 0 0 / 3 0 0 0 C o m p a c t I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 1 1 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Block wiring diagram of the PCB board...
  • Page 12: Heat Pump Installation And Connection

    I n s t a l l a t i o n a n d u s e r m a n u a l H P 2 4 0 0 / 3 0 0 0 C o m p a c t V e r s i o n : 0 1 / 2 0 1 8 P a g e 1 2 / 2 8 4.
  • Page 13: Connection To Water Filtration Circuit

    H P 2 4 0 0 / 3 0 0 0 C o m p a c t I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 1 3 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Connection to water filtration circuit...
  • Page 14: Needed Components For Connection To Water Circuit

    I n s t a l l a t i o n a n d u s e r m a n u a l H P 2 4 0 0 / 3 0 0 0 C o m p a c t V e r s i o n : 0 1 / 2 0 1 8 P a g e 1 4 / 2 8 Needed components for connection to water circuit...
  • Page 15 H P 2 4 0 0 / 3 0 0 0 C o m p a c t I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 1 5 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Scheme: Connection of the compact heat pump into the water filtration circuit of the...
  • Page 16: Electrical Connection

    I n s t a l l a t i o n a n d u s e r m a n u a l H P 2 4 0 0 / 3 0 0 0 C o m p a c t V e r s i o n : 0 1 / 2 0 1 8 P a g e 1 6 / 2 8 Electrical connection...
  • Page 17: Control Of The Circulation Pump

    28°C Control of the circulation pump Microwell swimming pool heat pump is able to control the circulation pump. In principle should the heat pump be in need for heating/cooling it will automatically turn the circulation pump on. In order to enable this control, the circulation pump must be connected to the heat pump electrically refer to section 3.6 Block wiring diagram of the PCB board...
  • Page 18: Separate Water Circuit

    I n s t a l l a t i o n a n d u s e r m a n u a l H P 2 4 0 0 / 3 0 0 0 C o m p a c t V e r s i o n : 0 1 / 2 0 1 8 P a g e 1 8 / 2 8 circulation pump off.
  • Page 19: Regulation

    H P 2 4 0 0 / 3 0 0 0 C o m p a c t I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 1 9 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 5.
  • Page 20: General Heat Pump Control

    I n s t a l l a t i o n a n d u s e r m a n u a l H P 2 4 0 0 / 3 0 0 0 C o m p a c t V e r s i o n : 0 1 / 2 0 1 8 P a g e 2 0 / 2 8 General heat pump control...
  • Page 21: Heat Pump Operational Modes

    H P 2 4 0 0 / 3 0 0 0 C o m p a c t I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 2 1 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Heat pump operational modes...
  • Page 22: Child Lock

    I n s t a l l a t i o n a n d u s e r m a n u a l H P 2 4 0 0 / 3 0 0 0 C o m p a c t V e r s i o n : 0 1 / 2 0 1 8 P a g e 2 2 / 2 8 Automatic turning off...
  • Page 23: Setting Of The Operating Parameters

    H P 2 4 0 0 / 3 0 0 0 C o m p a c t I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 2 3 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 parameter ‘14’...
  • Page 24: Accessories

    I n s t a l l a t i o n a n d u s e r m a n u a l H P 2 4 0 0 / 3 0 0 0 C o m p a c t V e r s i o n : 0 1 / 2 0 1 8 P a g e 2 4 / 2 8 Figure...
  • Page 25: Condensate Tray Defrost

    H P 2 4 0 0 / 3 0 0 0 C o m p a c t I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 2 5 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 Condensate tray defrost...
  • Page 26: Winterizing

    I n s t a l l a t i o n a n d u s e r m a n u a l H P 2 4 0 0 / 3 0 0 0 C o m p a c t V e r s i o n : 0 1 / 2 0 1 8 P a g e 2 6 / 2 8 in section 3.5 Security and control systems...
  • Page 27: Heat Pump Season Start

    H P 2 4 0 0 / 3 0 0 0 C o m p a c t I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 2 7 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 7.
  • Page 28: Failure Reports

    I n s t a l l a t i o n a n d u s e r m a n u a l H P 2 4 0 0 / 3 0 0 0 C o m p a c t V e r s i o n : 0 1 / 2 0 1 8 P a g e 2 8 / 2 8 Air IN...
  • Page 29 H P 2 4 0 0 / 3 0 0 0 C o m p a c t I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 2 9 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 acoustic warning...
  • Page 30: Troubleshooting - Save Time And Money

    I n s t a l l a t i o n a n d u s e r m a n u a l H P 2 4 0 0 / 3 0 0 0 C o m p a c t V e r s i o n : 0 1 / 2 0 1 8 P a g e 3 0 / 2 8 Troubleshooting –...
  • Page 31: Maintanance & Warranty

    H P 2 4 0 0 / 3 0 0 0 C o m p a c t I n s t a l l a t i o n a n d u s e r m a n u a l P a g e 3 1 / 2 8 V e r s i o n : 0 1 / 2 0 1 8 High pressure on compressor...
  • Page 32: Warranty

    Installation and user manual is excluded from warranty coverage. Distributed by: Manufacturer: MICROWELL, spol. s r.o. SNP 2018/42, 927 01 Sala, Slovakia tel.: +421/31/702 0540 fax: +421/31/702 0542 e-mail: microwell@microwell.sk...