The remote receiver of a channel relay output. The TL-1, recognize the signal sent by the issuer to check the code and
connect the output while the transmitter button is engaged. Supports setting of between 13,122 security code combinations.
Issuers supports Cebek TL-5, TL-6, TL11, TL-12, TL-13 , TL-14, TL-15 and TJ Microswitches incorporates code selection,
antenna input, output and LED indicator terminals.
POWER SUPPLY.
The TL-1 must be supplied with a voltage of 12 V. DC. properly stabilized, so we recommend not using
simple feeders or rectifiers, which adversely affect the operation of the module, power supply sinouna. We suggest the FE-2
or FE-103, which is well suited to the needs of the circuit, or for portable applications a battery of 12 V. Install a fuse and a
switch as illustrated. Both are necessary for the adequate protection of the module for your own safety, as reflected in the CE
standard. Asked the layout of the output of the source or battery, the positive and negative power to the corresponding input
terminals indicated in the drawing. Finally make sure that the installation was successful.
OPERATION.
All remote controls often Cebek working on 433.92 MHz approved for TL-1 features an array of micro-
switches, SW-1, through which you can configure a security code that makes the difference and unique to each module.
Have up to 13,122 different combinations to make your own code. Look at the fig. 1, there micro-battery switch, SW-1 has 8
switches, each of which may be located in three different positions, "-", "0" and "+". Change the layout from the factory and
picking modifying their code switches staff. Note that there is communication with the issuer, it must be configured with the
same code used in the receiver. Once you have set the sender and the receiver with the desired code, activate the power
module. Then press the button on the transmitter, while you hold the output will remain connected, when released, the output
is disconnected
INSTALLING THE ANTENNA.
performance. Noting the General Wiring and install the antenna. This may be any metal rod with a length of 130 mm. Or an
outdoor antenna or C-0509, C-0510.
Output configuration. In addition to control by its corresponding transmitter, TL-5, the remote channel receiver supports the
use of TL-6, TL-11, TL-12, TL-13, TL-14, TL-15 and Tl-16. The factory setting is provided in use for a single button
(JP1 jumper closed). To control the TL-1 through TL-6, TL12, TL-14, TL-16 having the choice of two buttons on the transmitter,
which connects the output of the receiver, you can simply remove the closing piece "JP" JP-1 jumper and leave it in the open
state. Remember that for the TL-1 for use with the issuer of a JP-1 channel should be closed
Piece
JP
RECEIVER REMOTE CONTROL
The module required for clear reception an outdoor antenna that lets you optimize
Jumper without closing
(Open)
www.cebek.com - sat@cebek.com
TL-1
TECHENICAL CHARACTERISTICS
Supply Voltage. .................................... 12 V. DC
Minimum consumption. ........................ 15 mA.
Maximum consumption. .................. ...... 55 mA.
Working frequency. .......................... 433.92 Mhz. Max.
for output. ............................................ 3 A.
Measures. ........................................... 72 x 76 x 26 mm.
Weight .......................................... ...... 51 gr.
DIN Rail ............................................... Ref . C-7565
jumper closed