Download Print this page

CEBEK RJ-5 Quick Start Manual

Long distance infra red receiver

Advertisement

Quick Links

E L E C T R O N I C C I R C U I T S
The RJ-5 module is an infra-red receiver could receive signal from RJ-4 receiver up to 8 meters as maximum.
Output with relay, the maximum load at the output is 5 A.
Because all hereafter information are important, please read carefully the instruction manual to obtain a correct
TECHNICAL CHARACTERISTICS.
Voltage ................................................................................................... 12V. D.C.
Maximum Consumption ........................................................................ 50 mA.
Maximum Output Load ......................................................................... 5 A. (220 VAC)
Maximum Reach .................................................................................... 8 m.
Protection Against Polarity Inversions ..................................................... Yes.
Sizes ....................................................................................................... 70 x 55 x 30 mm
OPERATING.
OPERATING
The RJ-5 has to be supplied by 12 VDC, and we suggest you our FE-2 module which have been specially designed to
answer to the circuit needs.
Connect the positive terminal of the power supply to the positive terminal of the module and do the same thing with
the negative terminal. Place the power supply as near as possible of the RJ-5 module. Verify that the assembly have
been correctly done.
INSTALLATION
Do not forget that the place and the circuit connection will be essential to obtain a perfect module's operating. Place
the circuit on a solid and plane surface and bring the emitter into alignment with the receiver. This alignment has to
be vertical and horizontal (at the same height that the receiver). See the "wiringmap"
The direct light could damage the RJ-5, mainly if it is the sun light ; for this reason, we suggest you to protect the
CONNECTION.
Power Supply
RJ-5
1
Normally Open
Common
Normally Closed

Advertisement

loading

Summary of Contents for CEBEK RJ-5

  • Page 1 This alignment has to be vertical and horizontal (at the same height that the receiver). See the "wiringmap" The direct light could damage the RJ-5, mainly if it is the sun light ; for this reason, we suggest you to protect the CONNECTION.
  • Page 2 The used power supply for emitter and receiver have to be different. If you could not use 2 different power supply, try to install the power supply as near as possible of the RJ-5 and use cables till RJ-4 emitter.