10 PROGRAM SELECTION

Up to 10 programs can be store in the the TS6500 Mixer.
1. Press the Set button (Fig. 5) to highlight the program number
selection.
2. Press the (+) or (-) buttons to select desired program.
3. Press the Set button to exit.

11 CYCLE COUNTER RESET

The cycle counter can record up to 99999 mix cycle. To reset the
cycle counter follow below instructions:
1. Press and hold Setup button for 3 seconds to enter setup mode.
2. Once the setup mode is displayed, ress and hold Setup button
again until the cycle counter reset to "00000"

12 CARTRIDGE HOLDER INSTALLATION

Refer to Figure 16 and 17
The TS6500CIM-6 is setup to mix the 6.0 oz.(177ml) kit. To mix the
2.5 (74ml) or 8.0 oz.(237ml) kit the cartridge holder needs to be re-
install at different mounting locations as shown in Fig. 10.
Mounting Location for 2.5 oz.
(74ml) Kit
Mounting Location for 6.0
oz.(177ml) Kit
Mounting Location for 8.0 oz.
(237ml) Kit
Figure 16.0 Mounting Location
19
The cartridge holder can be installed in a few simple steps
1. Pull the release knob and push the Fluid level sensor assembly
to the left
2. Loosen the locking screw by turning it counter clockwise.
3. Rotate the cartridge holder outward and pull it up to remove from
the machine
4. Install new cartridge holder in reverse order
5. Pull release knob to rotate fluid level sensor assembly back into
position.
Release Knob
Fluid Level Sensor
Fluid Level Sensor Assembly
Figure 17.0 Cartridge Holder
Cartridge Holder
Locking Screw
20