Trotec Qube+ Original Instructions Manual

Insulation drying unit

Advertisement

Quick Links

QUBE+
EN
ORIGINAL INSTRUCTIONS
INSULATION DRYING UNIT

Advertisement

Table of Contents
loading

Summary of Contents for Trotec Qube+

  • Page 1 QUBE+ ORIGINAL INSTRUCTIONS INSULATION DRYING UNIT...
  • Page 2: Table Of Contents

    Information about the device.......... 4 Transport and storage............ 7 Assembly and installation............. 8 Qube+ Start-up................ 10 Operation ................ 11 https://hub.trotec.com/?id=40717 Errors and faults.............. 13 Safety Maintenance ................ 15 Read this manual carefully before starting or using the Technical annex.............. 22 device. Always store the manual in the immediate vicinity Disposal ................ 26...
  • Page 3 Intended use Warning Risk of suffocation! The Qube+ is to be used in low pressure mode for insulation Do not leave the packaging lying around. Children may drying of floating screeds, flat roofs (warm roof constructions) use it as a dangerous toy. and hollow floorings.
  • Page 4: Information About The Device

    The device is equipped with a touch screen with LC display. Information about the device It provides information on the operating stage, air flow rate etc. The background colour of the LC display changes according to Device description the traffic light principle to indicate how suitable your drying The Qube+ consists of only one device and is 50 % lighter and installation is.
  • Page 5 Device depiction Designation Connection for discharge of process air Connector 50 mm Service socket (tamper-proof) Holder for storage with release button for the height-adjustable telescopic push handle Power cable Designation MID meter Telescopic push handle Upper part with turbine Air inlet for cooling Tension lock Lower part with pump Wheel...
  • Page 6 Schematic detail view with filters Designation F7 air filter Air filter cover F8 filter sleeve for HEPA filter (optional) HEPA filter (optional) Pump Coarse filter Coarse filter fixation grid Demister holder Demister Wing nut Cage G4 filter sleeve Spring contacts for electrical connection insulation drying unit Qube+...
  • Page 7: Transport And Storage

    Storage Transport and storage Before storing the device, proceed as follows: Note • Empty and clean the condensation tank prior to storage. If you store or transport the device improperly, the • Hold onto the mains plug while pulling the power cable out device may be damaged.
  • Page 8: Assembly And Installation

    Assembly Assembly and installation Remove the packaging. Remove any transport locks from the Scope of delivery and accessories supply connections. Accessories and supplies contained in the scope of delivery of The wheels are already preassembled. the Qube+: The telescopic push handle is preassembled and can be adjusted in height: Quantity and designation Art.
  • Page 9 Connecting the drain hose TTKwic quick couplings The device must be connected to an appropriate drain or As standard, the device comes with two integrated TTKwic collection container via a drain hose so that the device can drain quick couplings (7), where condensate discharge hoses of up to the accumulated water from the water tank if required.
  • Page 10: Start-Up

    Positioning the device Start-up When setting up the device, make sure that the warm air • Use suitable hoses (observe number and diameter) to set generated by the device is discharged. The room temperature up the drying installation. should not exceed 35 °C. •...
  • Page 11: Operation

    Setting the power stages and operating modes Operation The device comes with 4 power stages, a boost mode, a Operating elements whisper mode and the TTKwic mode. Whisper mode can be activated by pressing the whisper mode button (40). Setting the power stages and the boost mode In boost mode, the motor runs at its maximum performance.
  • Page 12 Key lock Emptying the tank To prevent an accidental maladjustment of the device settings, Info the device is fitted with a key lock function. The drain hose must be connected and guided to an Simultaneously press and hold the plus (38) and minus (37) appropriate drain or collection container.
  • Page 13: Errors And Faults

    Little or no air is sucked in or blown out: device to a specialist company for cooling and air-conditioning • Check the installation and add relief openings to improve or to Trotec for repair. the air circulation and to operate the compressor within its operating range if necessary.
  • Page 14 Fault messages Fault message Cause Remedy The following fault messages may appear on the LC display: abpumpen... The pump drains No action required. (pumping off) the accumulated If the pump is to run Fault message Cause Remedy water. permanently, the water Behaelter getrennt! The electrical Check whether the...
  • Page 15: Maintenance

    Warning of electrical voltage Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec. Note Observe the overvoltage protection. The device comes equipped with an overvoltage protection.
  • Page 16 2. If required, connect a new drain hose. Cleaning or replacing the filters The filters must be cleaned or replaced as soon as they are dirty. If the Filter wechseln! message appears on the display, the filter inside the device (G4 or F8 filter sleeve or HEPA filter) must be replaced as it does not allow a sufficient quantity of air to pass.
  • Page 17 Replacing the air filter Replacing the G4 filter sleeve ü The device is switched off and disconnected from the If the Filter wechseln! message appears on the display, the mains. G4 filter sleeve inside the device must be replaced as it does not ü...
  • Page 18 4. Remove the G4 filter sleeve from the cage. Cleaning the demister ü The device is switched off and disconnected from the mains. ü The residual water has been drained. ü The upper part has been removed (see Replacing the G4 filter sleeve).
  • Page 19 4. Loosen the quick coupling of the hose (43) on the tank Cleaning the pump filter wall. ü The device is switched off and disconnected from the 5. Slightly lift the sheet that is fixating the pump. mains. ü The residual water has been drained. ü...
  • Page 20 5. Rinse the coarse filter and the coarse filter fixation under Cleaning the coarse filter (filter mat) running water. ü The device is switched off and disconnected from the ð Exchange the coarse filter and the coarse filter fixation mains. if required (e.g.
  • Page 21 3. Screw the HEPA filter onto the upper part. 4. Remove the F8 filter sleeve from the HEPA filter. 5. Place the new F8 filter sleeve around the HEPA filter. Make sure that the sleeve surrounds the filter completely. 6. Screw the HEPA filter back onto the upper part. 4.
  • Page 22: Technical Annex

    Technical data Technical annex Technical data and equipment Qube+ Suitable for surfaces sized up to (low pressure) power stage 1 10 m power stage 2 25 m power stage 3 50 m power stage 4 85 m Maximum pressure (low pressure) 220 mbar Air flow rate (freely blowing) 250 m Defined volumetric flow optimum (sucking in) of the HiDry whisper mode...
  • Page 23 Technical data and equipment Qube+ TTKwic operating mode ■ Height-adjustable telescopic push handle ■ Cable holder with fixable plug ■ Thermal protection ■ ■ Maintenance quick release fasteners maximum air flow rate of the fan motor (not integrated) vvia Optiflow NT multi-function display What does MID-compliant mean? In some areas, the Measuring Instruments Directive (MID) replaces the previous regulation of national authorization and subsequent calibration.
  • Page 24 Exploded assembly drawing Info The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions. insulation drying unit Qube+...
  • Page 25 List of spare parts Pos. no. Article number Designation 7.600.000.006 swivel castor 50/19 P10006255 telescopic push handle 7.310.000.897 handle 7.600.000.001 plain bearing wheel 200/50 with black end cap 7.200.000.001 connector 50 mm aluminium P10003459 housing Qube+ filter insert 7.160.000.221 HEPA filter module H13 incl. F8 prefilter sleeve P10000203 demister insert P10002223...
  • Page 26: Disposal

    Annex II, part 1, Section A addresses can be obtained from your municipality or local administration. For further return options provided by us please Herewith, we – Trotec GmbH & Co. KG – declare that the refer to our website www.trotec24.com. machinery designated below was developed, constructed and...
  • Page 27 Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...

Table of Contents