Information marked with this symbol indicates that the are damaged! instructions must be observed. • The electrical connection must correspond to the specifications in chapter Technical data. condenser dryer DH 160 / TTK 1600...
2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket. 3. Do not reconnect a defective device to the mains. condenser dryer DH 160 / TTK 1600...
Page 5
Air inlet / suction side with filter Energy meter (MID-compliant) Foot Power cable holder Condensate drain hose connection Frame (handle) Pump drain hose connection Connections 6, 7, 8 (see device depiction DH 160) Power connection Wheels Energy meter (MID-compliant) condenser dryer DH 160 / TTK 1600...
• dry and protected from frost and heat • in an upright position where it is protected from dust and direct sunlight • with a cover to protect it from invasive dust, if necessary condenser dryer DH 160 / TTK 1600...
Page 7
• Make sure that no curtains or other objects interfere with the air flow. • When positioning the device, particularly in wet areas, secure it locally with an RCD (residual current device) which complies with the respective regulations. condenser dryer DH 160 / TTK 1600...
Page 8
If the air flow rate performance and result in damage to the device. deviates too strongly, the dehumidification performance • Make sure that the air filter is installed before switching will not be achieved. the device on. condenser dryer DH 160 / TTK 1600...
ð The desired humidity value is displayed. external hygrostat (option) 17 HOURS button Number of operating hours is displayed 18 Increase value For increasing the desired relative button humidity level (30 % to 80 %) For deactivating continuous operation condenser dryer DH 160 / TTK 1600...
• If necessary, remove the condensation drain hose and any residual fluid from it. • Empty the condensation tank, if need be. • Clean the device according to the Maintenance chapter. • Store the device according to the Storage chapter. condenser dryer DH 160 / TTK 1600...
Disconnect the device from the mains and let it cool down for approx. 10 minutes before reconnecting it. • The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify. condenser dryer DH 160 / TTK 1600...
Page 12
• The device does not operate due to • Check the outside temperature (temperatures above 35 °C can be excessive ambient temperatures. critical). • When the temperature drops, the error message will be reset automatically. High-pressure switch condenser dryer DH 160 / TTK 1600...
Replace the air filter Check for damage Check the attachment screws Test run Empty the condensation tank and/ or drain hose Check the condensate pump and connections, and clean if necessary condenser dryer DH 160 / TTK 1600...
Page 15
4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for cooling and air- conditioning or by Trotec. 5. Put the air filter back in. 2. Remove the air inlet cover with filter (4) from the device. condenser dryer DH 160 / TTK 1600...
Page 16
1. Loosen the three attachment screws at the service panel with 1/4 turn. 5. Reconnect the hose lines and check all hose connections. 6. Reattach the service panel to the device by turning the attachment screws 1/4 turn. condenser dryer DH 160 / TTK 1600...
A: top: 80 cm 80 cm B: rear: 80 cm 80 cm C: side: 80 cm 80 cm D: front: 50 cm 50 cm Operating temperature chart Dehumidification chart Dehumidification performance [l/24h] RH [%] condenser dryer DH 160 / TTK 1600...
Manufacturer and name of the authorised representative of the technical documentation: Trotec GmbH & Co. KG Grebbener Straße 7, D-52525 Heinsberg Phone: +49 2452 962-400 E-mail: info@trotec.de Place and date of issue: Heinsberg, 28.05.2018 Detlef von der Lieck, Managing Director condenser dryer DH 160 / TTK 1600...
Page 19
Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...