Summary of Contents for Trotec DH 310

  • Page 1 DH 160 / DH 310 ORIGINAL INSTRUCTIONS CONDENSER DRYER...
  • Page 2: Table Of Contents

    • Ensure that all electric cables outside of the device are Information marked with this symbol indicates that the protected from damage (e.g. caused by animals). Never instructions must be observed. use the device if electric cables or the power connection are damaged! condenser dryer DH 160 / DH 310...
  • Page 3 – instruments, devices, files Hold onto the mains plug while pulling the power cable – electric control devices, boiler plants, turbines and pipe out of the mains socket. systems in power plants – moisture-sensitive loads etc. condenser dryer DH 160 / DH 310...
  • Page 4: Information About The Device

    Moreover, the device is fitted with an energy meter as standard. The device can reduce the relative humidity of a room to approx. 30 %. Because of the heat radiation generated during operation, the room temperature may rise slightly. condenser dryer DH 160 / DH 310...
  • Page 5: Transport And Storage

    (MID-compliant) and heat. • Store the device in an upright position where it is protected from dust and direct sunlight. • If required, use a cover to protect the device from invasive dust. condenser dryer DH 160 / DH 310...
  • Page 6: Assembly And Installation

    60 % is sufficient. In storage facilities and archives, the When positioning the device, observe the minimum distance humidity should not exceed approx. 50 %. from walls or other objects as described in the chapter Technical annex. condenser dryer DH 160 / DH 310...
  • Page 7 All devices are equipped with a phase failure relay. If one phase is missing or if there is no clockwise rotating field, the indicator light at the relay will be off and the industrial dryer will not start. condenser dryer DH 160 / DH 310...
  • Page 8: Operation

    The device keeps running until reaching the desired relative • Indication of the error code, see room humidity. Once the desired relative room humidity is chapter Errors and faults exceeded, the compressor and fan switch back on. condenser dryer DH 160 / DH 310...
  • Page 9: Available Accessories

    Dehumidification is briefly interrupted during defrosting. The fan keeps running. The duration of the defrost process can vary. Do not switch off the device during automatic defrost. Do not remove the mains plug from the mains socket. condenser dryer DH 160 / DH 310...
  • Page 10: Errors And Faults

    The device is loud or vibrates: • Check whether the device is set up in a stable and upright position. Condensate is leaking: • Check the device for leaks. condenser dryer DH 160 / DH 310...
  • Page 11 • Clean the pump as described in the Maintenance chapter. • The pump or float switch may be • Please contact the customer service if the pump or the float switch is defective. defective. High-pressure switch condenser dryer DH 160 / DH 310...
  • Page 12: Maintenance

    11. Date: ........12. Date: ........Signature: ........Signature: ........Signature: ........Signature: ........13. Date: ........14. Date: ........15. Date: ........16. Date: ........Signature: ........Signature: ........Signature: ........Signature: ........condenser dryer DH 160 / DH 310...
  • Page 13 • Hold onto the mains plug while pulling the power cable out of the mains socket. Warning of electrical voltage Tasks which require the device to be opened must only be carried out by authorised specialist companies or by Trotec. condenser dryer DH 160 / DH 310...
  • Page 14 4. Allow the filter to dry completely. Do not insert a wet filter into the device! 5. Reinsert the air filter into the device. 6. Reattach the air inlet cover (4) to the device. 2. Remove the air inlet cover with filter (4) from the device. condenser dryer DH 160 / DH 310...
  • Page 15 5. Reconnect the hose lines and check all hose connections. 6. Reattach the service panel to the device by turning the attachment screws 1/4 turn. 2. Remove the service panel from the device. 3. Remove the hose lines from the pump connections. condenser dryer DH 160 / DH 310...
  • Page 16: Technical Annex

    A: top: 80 cm 80 cm B: rear: 80 cm 80 cm C: side: 80 cm 80 cm D: front: 50 cm 50 cm Operating temperature chart Dehumidification chart Heat Power emission input * at 70 % RH Dehumidification performance [l/24h] RH [%] condenser dryer DH 160 / DH 310...
  • Page 17 Circuit diagram DH 160 condenser dryer DH 160 / DH 310...
  • Page 18 Circuit diagram DH 310 condenser dryer DH 160 / DH 310...
  • Page 19 PANEL RIGHT SIDE RAL9010 BUCC. REAR PANEL FILTER SUPPORT RAL9010 BUCC. TOP PANEL RAL9010 BUCC. AIR FILTER DELIVERY GRILLE RAL9010 BUCC, PANEL LEFT SIDE RAL9010 BUCC. REAR PANEL UPPER RAL9010 BUCC. FRONT PANEL RAL9010 BUCC. condenser dryer DH 160 / DH 310...
  • Page 20 Frame DH 160 Note: The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions. condenser dryer DH 160 / DH 310...
  • Page 21 POWER SUPPLIED PANEL RAL9005 MAIN SWITCH COMPLETE RECEPTACLE SUPPORT RAL9010 BUCC. BUCC. PROTECTION DOOR DISPLAY RECEPTACLE PROTECTION ENERGY METER LOWER CLOSURE COMMAND PANEL RAL9005 BUCC ENERGY METER UPPER CLOSURE COMMAND PANEL RAL9005 BUCC condenser dryer DH 160 / DH 310...
  • Page 22 ELECTRIC VALVE (EV2) PROTECTION HUMIDITY SENSOR RAL9010 BUCC. BRACKETS FIXING EVAPORATOR ELECTRIC VALVE (EV1) HUMIDITY SENSOR TEMPERATURE PROBE SUPPORT ELECTRIC VALVE TEMPERATURE PROBE RAL9010 BUCC. DEFROST THERMOSTAT THERMOSTATIC VALVE TRAY FILTER BELT RAL9010 BUCC. condenser dryer DH 160 / DH 310...
  • Page 23 MAIN ELECTRICAL CABINET RAL90110 BUCC. CONTACTOR 7,5 KW FEMALE CONNECTOR 6 PIN MODULAR TIMER GENERAL SWITCH RELE' PHASE CONTROL MALE CONNECTOR 6 PIN WITH BRIDGE PCB DIGIT SOFTWARE 01XX CLOSING ELECTRICAL CABINET RAL9010 BUCC. condenser dryer DH 160 / DH 310...
  • Page 24 BACK SUPERIOR PANEL RAL9010 BUCC. PANEL RIGHT SIDE RAL9010 BUCC. BACK PANEL FILTER SUPPORT RAL9010 BUCC. TOP PANEL RAL9010 BUCC. AIR FILTER DELIVERY GRILLE RAL9010 BUCC. PANEL LEFT SIDE RAL9010 BUCC. DELIVERY SQUARE CANAL RAL9010 BUCC. condenser dryer DH 160 / DH 310...
  • Page 25 Frame DH 310 Note: The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions. condenser dryer DH 160 / DH 310...
  • Page 26 ENERGY METER. CABINET RAL9005 UPPER TRANSVERSE RAL9010 BUCC. BUCC. PANEL FIXING SCREW COMPLETE REINFORCEMENT COMMANDS REAR RIGHT RISER RAL9010 BUCC. RISER RAL9010 BUCC. RECEPTACLE SUPPORT RAL9010 LABEL COMMAND PANEL REAR TRANSVERSE MACHINE BUCC. RAL9010 BUCC. condenser dryer DH 160 / DH 310...
  • Page 27 ELECTRIC VALVE COIL TEMPERATURE PROBE BRACKETS FIXING EVAPORATOR ELECTRIC VALVE (EV1) TEMPERATURE PROBE DEFROST THERMOSTAT SUPPORT ELECTRIC VALVE HUMIDITY SENSOR RAL9010 BUCC. TRAY LOW PRESSURE CONTROL PROTECTION HUMIDITY SENSOR RAL9010 BUCC. TEMPERATURE PROBE THERMOSTATIC VALVE condenser dryer DH 160 / DH 310...
  • Page 28 CONTROL PCB (up to S.N. 1130017669) MALE CONNECTOR 6 PIN WITH BRIDGE CONTROL PCB (from S.N. 1130017670) CLOSING ELECTRICAL CABINET RAL9010 BUCC. PCB FOR NEW HPS LOGIC (from S.N. 1130017670) CONTACTOR 7,5 KW condenser dryer DH 160 / DH 310...
  • Page 29: Disposal

    Declaration of conformity Declaration of conformity in accordance with the EC Machinery Directive 2006/42/EC, Annex II, Part 1, Section A We – Trotec GmbH – declare in sole responsibility that the product designated below was developed, constructed and Joachim Ludwig, Managing Director produced in compliance with the requirements of the EC Machinery Directive in the version 2006/42/EC.
  • Page 30 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...