Pentair Raychem SENZ Quick Start Manual page 18

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
3. TECHNICAL SPECIFICATION
Purpose of control:
Method of mounting:
Supply voltage:
Main power switch:
Relay output:
Protection class:
Terminals:
Terminal wire size:
Floor sensor with 3m cable: 12k @ 25°C +/- 0,75°C
Maximum length of floor
sensor cable:
Control modes:
Temperature regulation
method:
Type of action:
Control pollution degree:
Software class:
Overvoltage category:
Rated impulse voltage:
Ball pressure temperature: 125°C
SELV limits realized:
18
Electronic thermostat for
electric floor heating
Flush mounting
230VAC +/- 10%, 50Hz
2-pole
230V, max. 13A
IP21 (IP44 with accessory
1244-017779)
2,5 mm² screw cage clamp
2,5 mm
2
(no:38165)
100m, 2 x 1,5mm²
(230VAC cable)
Floor sensor (active when
floor sensor installed)
Room sensor with floor
limiter (active when floor
sensor installed)
Room sensor (active when
no floor sensor installed)
No sensor % regulator
with cycles of 20 minutes
(active when no floor sensor
installed)
PWM (pulse width
modulation) with PI control
loop
Type 1.B.
2
A
III
4kV
24V

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Raychem senz wifi

Table of Contents