Derating Curve
The area within the curve represents the safe
operating range for the module under various
conditions of user supplied 24V dc supply
voltages and ambient temperatures.
= Safe operating area
Resolution Curves for Thermocouples
C
Resolution
F
1000Hz
500Hz
250Hz
10–100Hz
102.4
25.60
6.40
0.80
184.3
46.08
11.52
1.44
89.60
22.40
5.60
0.70
161.3
10.08
40.32
1.26
76.80
19.20
4.80
0.60
138.2
34.56
8.64
1.08
64.00
16.00
4.00
0.50
115.2
28.80
7.20
0.90
51.20
12.80
3.20
0.40
92.16
23.04
5.76
0.72
38.40
9.60
2.40
0.30
69.12
17.28
4.32
0.54
25.60
6.40
1.60
0.20
46.08
11.52
2.88
0.36
12.80
3.20
0.80
0.10
23.04
5.76
1.44
0.18
0
Template revised June 23, 1995
User Applied 24V dc Supply versus Ambient Temperature
31.2
24.0
19.2
Type B Thermocouple
–300
0
–150
150
300
–508
32
–238
302
572
o
o
25
C
40
Ambient Temperature
900
450
600
750
1050
1652
1922
842
1112
1382
C
Temperature
F
Specifications
A–3
o
o
C
50
C 55
C
1200
1350
1500
1650
1800
2462
2192
2732
3002
3272
Publication 1794-6.5.7 – March 1997