Bard PH1224 Installation Instructions Manual

Single package heat pumps
Table of Contents

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS

Bard Manufacturing Company
Bryan, Ohio 43506
Since 1914...Moving ahead, just
as planned.
SINGLE PACKAGE
HEAT PUMPS
MODELS
PH1224
PH1230
PH1236
Manual :
2100-344
File:
Volume II Tab 11
Date:
08-21-98
© Copyright 1998

Advertisement

Table of Contents
loading

Summary of Contents for Bard PH1224

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS SINGLE PACKAGE HEAT PUMPS Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. MODELS PH1224 PH1230 PH1236 Manual : 2100-344 File: Volume II Tab 11 Date: 08-21-98 © Copyright 1998...
  • Page 2: Table Of Contents

    Contents Getting Other Informations and Publications ... 1 General Instructions ... 3 Important ... 3 Shipping Damage ... 3 General ... 3 Field-Installed Heater Packages (Optional) ... 3 Installation ... 5 Location ... 5 Typical Installations ... 5 Condensate Drain Trap ... 8 Air Filters ...
  • Page 3: Getting Other Information And Publications

    Getting Other Information and Publications These publications can help you install the air conditioner or heat pump. You can usually find these at your local library or purchase them directly from the publisher. Be sure to consult current edition of each standard. National Electrical Code ...
  • Page 4: Table 1 Electrical Data

    75 degree C cooper wire size, basic unit only. OPTIONAL FIELD INSTALLED HEATER PACKAGES ONLY TO BE USED WITH THE HEAT PUMP MODELS INDICATED OPTIONAL FIELD-INSTALLED ELECTRIC HEATER TABLE . r t & Time delay fuses or “HACR” type circuit breakers must be used for 60 and smaller sizes. Standard fuses or circuit breakers are suitable for sizes 70 and larger.
  • Page 5: General Instructions

    FIELD INSTALLED HEATER PACKAGES (OPTIONAL) These packaged heat pumps are manufactured without supplementary electric heaters. Supplementary heaters EH3P series (to fit PH1224, PH1230, and PH1236) are available for simple, fast, field installation. A separate field power circuit is required for the supplementary heaters.
  • Page 6: Specifications

    PREFABRICATED ROOF CURB SPECIFICATIONS HEAVY GAUGE GALVANIZED WITH WOOD NAILING STRIP, WELDED/LEAKPROOF ONE PIECE CONSTRUCTION – READY TO INSTALL MIS-1177 *Duct Sizing Information Return Air Dimension “C” is length Return Air Dimension “H” is width MIS-1178 Manual 2100-344 Page FIGURE 1 CURB AND ROOF DETAILS Supply Air Dimension “C”...
  • Page 7: Installation

    LOCATION GENERAL The unit must be located outside, or in a well ventilated area. It must not be in the space being heated or cooled. A sound absorbing material should be considered if the unit is to be installed in such a position or location that might cause transmission of sound or vibration to the living area or adjacent buildings.
  • Page 8: Figure 3 Elevated Mounting Platforms

    FIGURE 3 ELEVATED MOUNTING PLATFORMS MIS-1183 FIGURE 4 AIRFLOW and SERVICE ACCESS CLEARANCES MIS-1185 Manual 2100-344 Page...
  • Page 9: Figure 5 Roof Top Application

    FIGURE 5 ROOF TOP APPLICATION (May also be required for ground level installations.) MIS-1176 FIGURE 6 SLAB MOUNTING AT GROUND LEVEL (Above 32° F Outside Temperature) MIS-1184 Manual 2100-344 Page...
  • Page 10: Condensate Drain Trap

    CONDENSATE DRAIN TRAP It is very important to provide a trap in the condensate drain line to allow a positive liquid seal in the line and assure correct drainage from the coil condensate pan. Install condensate drain trap shown in Figure 7. Use drain connection size or larger.
  • Page 11: Wiring - Main Power

    WIRING – MAIN POWER Refer to the unit rating plate for wire sizing information and maximum fuse size. Each outdoor unit is marked with a “Minimum Circuit Ampacity”. This means that the field wiring used must be sized to carry that amount of current. If field installed heaters are added to the basic unit, a second separate power supply circuit will be required.
  • Page 12: Thermostats

    THERMOSTATS See specific wiring information for the different models, heater KWs, and voltages. No automatic changeover position – must be manually placed in heat or cool. Reversing valve remains energized at all times system switch is in heat position (except during defrost cycle). No pressure equalization noise when thermostat is satisfied on either heating or cooling.
  • Page 13: Thermostat Indicator Lamps

    THERMOSTAT INDICATOR LAMPS The red lamp marked “EM. HT.” comes on and stays on whenever the system switch is placed in Em. Ht. position. The green lamp marked “Check” will come on if there is any problem that prevents the compressor from running when it is supposed to be.
  • Page 14: Start Up And Operation

    THREE PHASE SCROLL COMPRESSOR START UP INFORMATION Scroll compressors, like several other types of compressors, will only compress in one rotational direction. Direction of rotation is not an issue with single phase compressors since they will always start and run in the proper direction. However, three phase compressors will rotate in either direction depending upon phasing of the power.
  • Page 15: Figure 11 Heat Pump Control Board

    FIGURE 11 HEAT PUMP CONTROL BOARD MIS-1191 Manual 2100-344 Page...
  • Page 16: Service And Troubleshooting

    SERVICE AND TROUBLESHOOTING SERVICE HINTS 1. Caution homeowner to maintain clean air filters at all times. Also, not to needlessly close off supply and return air registers. This reduces air flow through the system which shortens equipment service life as well as increasing operating costs.
  • Page 17: Troubleshooting Guide

    i t n c r i t i u n i l i t c i t c i t c n i l t i c i t c l i o i t c ) y l i t c t i n l l i ) y l...
  • Page 18: Checking Temperature Sensor Check Out

    CHECKING TEMPERATURE SENSOR CHECK OUT 1. Disconnect temperature sensor from board and from outdoor coil. 2. Use an ohmmeter and measure the resistance of the sensor. Also use ohmmeter to check for short or open. TEMPERATURE F vs RESISTANCE R OF TEMPERATURE SENSOR Manual 2100-344 Page 3.
  • Page 19: Suction And Discharge Tube Brazing

    SUCTION AND DISCHARGE TUBE BRAZING Compliant Scroll compressors have copper plated steel suction and discharge tubes. These tubes are far more rugged and less prone to leaks than copper tubes used on other compressors. Due to different thermal properties of steel and copper, brazing procedures may have to be changed from those commonly used.
  • Page 20: Pressure Tables

    COOLING HEATING Low side pressure ± 2 PSIG High side pressure ± 5 PSIG Tables are based upon rated CFM (airflow across the evaporator coil and should be found under section titled “Refrigerant Charge” elsewhere in manual. If there is any doubt as to correct operating charge being in the system, the charge should be removed, system evacuated, and recharged to serial plate instructions.
  • Page 21: Wiring Diagrams

    Wiring Diagram (4098-123) printed from CAD to get size needed Manual 2100-344 Page...
  • Page 22 Wiring Diagram (4098-124) printed from CAD to get size needed Manual 2100-344 Page...
  • Page 23: Wiring Diagrams

    Wiring Diagram (4098-211) printed from CAD to get size needed Manual 2100-344 Page...