Bard WH Series Specifications

Bard WH Series Specifications

The wall-mount heat pumps - wh (60hz)
Hide thumbs Also See for WH Series:

Advertisement

WH-Series
Heating Capacities: 18,800 to 58,000 BTUH
Cooling Capacities: 19,000 to 56,500 BTUH
The Bard Wall-Mount Heat Pump is a self-contained energy efficient heating and
cooling system, which is designed to offer maximum indoor comfort at a minimal
cost without using valuable indoor floor space or outside ground space. This unit is
the ideal product for versatile applications such as: new construction, modular
offices, school modernization, telecommunication structures, portable structures or
correctional facilities. Factory or field installed accessories are available to meet
specific job requirements.

Engineered Features

Aluminum Finned Copper Coils:
Grooved tubing and enhanced louvered
fin for maximum heat transfer and
energy efficiency.
Twin Blowers:
Move air quietly. Most models feature
multispeed blower motors providing
airflow adjustment for high and low static
operation. Motor overload protection is
standard on all models.
Heat Pump Compressor:
Reciprocating compressor designed to
withstand higher compressor ratios and
longer operation than normal air
conditioning compressors. Equipped
with crankcase heater and dual
discharge muffler. Standard on all 2, 2½,
3 and 3½ ton models.
Scroll compressor designed for
increased efficiency, quieter operation
and improved reliability for longer life.
Eliminates need for crankcase heater
and suction accumulator. Standard on
all 1½, 4 and 5 ton models.
Galvanized 20 Gauge Zinc Coated
Steel Cabinet:
Cleaned, rinsed, sealed and dried
before the polyurethane primer is
applied. The cabinet is handsomely
finished with a baked on, beige textured
enamel, which allows it to withstand
1000 hours of salt spray tests per ASTM
B117-03.
Electrical Components:
Are easily accessible for routine
inspection and maintenance through a
right side, service panel opening.
Features a lockable, hinged access
cover to the circuit breaker or pull
disconnect switch.
Electric Heat Strips:
Features an automatic limit and thermal
cut-off safety control. Heater packages
are factory or field installed for all 1½
through 5 ton models. Features easy
slide-in field assembly with various
BTUH outputs.
Condenser Fan and Motor
Shroud Assembly:
Slide out for easy access.
• Complies with efficiency requirements of ASHRAE/IESNA 90.1-2004.
• Certified to ARI Standard 390-2003 for SPVU (Single Package Vertical Units).
• Commercial Product - Not intended for Residential application.
THE WALL-MOUNT
Refrigerant 22
One Inch, Disposable Air Filters:
Are standard equipment. Optional one
inch washable filters available and
filter racks permit the addition of 2"
pleated filter. Factory or field installed.
Solid State Electronic Heat Pump
Control:
Provides efficient 30, 60 or 90 minute
defrost cycle. A thermistor sensor,
speed up terminal for service and 10
minute defrost override are standard on
the electronic heat pump control.
High Pressure Switch:
Is built-in with a lockout circuit that
resets from the room thermostat.
Five Minute Compressor Time
Delay:
Short cycle protection is standard. Built
into the heat pump control.
Suction Accumulator:
Protects the reciprocating compressor
from refrigerant flood back and prevents
damage to the compressor bearing
surfaces. Not required on scroll
compressor applications.
Emergency Heat Circuit:
Permits continuous operation of the
system.
Barometric Fresh Air Damper:
Standard on all units. Allows up to 25%
outside fresh air.
Built-in Circuit Breakers:
Standard on all electric heat versions of
single and three phase (230/208 volt)
equipment. Toggle disconnects are
standard on all electric heat versions of
three phase (460 volt) equipment.
Slope Top:
Standard feature for water run-off.
Full Length Mounting Brackets:
Built into cabinet for improved
appearance and easy installation.
NOTE: Bottom mounting bracket
included to assist in installation.
Top Rain Flashing:
Standard feature on all models.
TM
HEAT PUMPS - WH (60HZ)
60Hz

Ventilation System Packages

All packages are designed
to meet your specific
ventilation requirements
utilizing
product. The ventilation
package is mounted within
the unit eliminating the
need for an exterior
mounted hood or damper
assembly on the unit. All
assemblies can be factory
installed, installed in the
field at time of installation
or as a retrofit system after
installation.
• Standard - Barometric
Fresh Air Damper
• Optional - Motorized
one
of
six
Fresh Air Damper
• Optional - Blank off Plate
• Optional - Commercial
Room Ventilator w/Exhaust
• CRV - Spring Return
• CRVP - Power Return
• Optional - Economizer
with Exhaust
• Optional - Energy
Recovery Ventilator
Form No.
Supersedes
Page
S3210-206
S3210-106
1 of 12

Advertisement

Table of Contents
loading

Summary of Contents for Bard WH Series

  • Page 1 Heating Capacities: 18,800 to 58,000 BTUH Cooling Capacities: 19,000 to 56,500 BTUH The Bard Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is...
  • Page 2 Capacity and Efficiency Ratings 1 Capacity is certified in accordance with ARI Standard 390-2003 and tested in accordance with ARI Standard 210/240-2003. 2 EER = Energy Efficiency Ratio, COP = Coefficient of Performance and are certified in accordance with ARI Standard 390-2003. SEER = Seasonal Energy Efficiency Ratio, HSPF = Heating Seasonal Performance Factor and are tested in accordance with ARI Standard 210/240-2003.
  • Page 3 Ventilation System Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a barometric fresh air damper as the standard ventilation package. All ventilation packages can be built-in at the factory, or field-installed at a later date.
  • Page 4 (cfm) Airflow Form No. S3210-206 Supersedes S3210-106 Page 4 of 12 (cfm) Airflow (cfm) Airflow...
  • Page 5 (cfm) Airflow (cfm) Airflow (cfm) Airflow (cfm) Airflow Form No. S3210-206 Supersedes S3210-106 Page 5 of 12...
  • Page 6 Performance and Application Data- WERV-*2B F ° Form No. S3210-206 Supersedes S3210-106 Page 6 of 12 ° 5 F ° ° 2 LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent...
  • Page 7 Form No. S3210-206 Supersedes S3210-106 Page 7 of 12...
  • Page 8 All dimensions are in inches. Dimensional drawings are not to scale. FRONT VIEW *NOTE: Top supply opening is optional and available factory-built only on models WH30 and WH36. Form No. S3210-206 Supersedes S3210-106 Page 8 of 12 " 5 " 0 "...
  • Page 9: Electrical Specifications

    C copper wire. All wiring must conform to the National Electrical Code and all local codes. Maximum KW that can operate with the heat pump on. These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electrical Code (latest version), Article 310 for power conductor sizing.
  • Page 10 Indoor Blower Performance - CFM at 230 or 460 Volts / y r l i o / y r Above data is with 1" standard throwaway filter and 1" washable filter. For optional 2" pleated filter - reduce ESP by .15 in. See installation instructions for maximum ESP information on various KW applications.
  • Page 11 Cooling Application Data - Outdoor Temperature n i l y t i l a t n i l n i l l a t n i l n i l l a t n i l n i l l a t n i l n i l l a t...
  • Page 12 3 For WH242-A, WH301-A, WH361-A and WH421-A models. The CMC-15 can be used with any control module combination. NOTE: The compressor anti-cycle relay is standard on all heat pump models. 4 The outdoor thermostat is adjustable from 0°F to 50°F. It is suitable for use as a compressor cut-off thermostat.

This manual is also suitable for:

Wh184Wh242Wh301Wh361Wh421Wh483 ... Show all

Table of Contents