Snell IQSDA32 User Instruction Manual

Intelligent reclocking high performance hd-sdi/sd-sdi distribution amplifiers

Advertisement

Quick Links

User Instruction Manual
IQSDA30/IQSDA32
Intelligent Reclocking High Performance HD-SDI/SD-SDI Distribution
Amplifiers
snellgroup.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IQSDA32 and is the answer not in the manual?

Questions and answers

Summary of Contents for Snell IQSDA32

  • Page 1 User Instruction Manual IQSDA30/IQSDA32 Intelligent Reclocking High Performance HD-SDI/SD-SDI Distribution Amplifiers snellgroup.com...
  • Page 2: Information And Notices

    Information in this manual and software are subject to change without notice and does not represent a commitment on the part of Snell Limited. The software described in this manual is furnished under a license agreement and can not be reproduced or copied in any manner without prior agreement with Snell Limited or their authorized agents.
  • Page 3: Table Of Contents

    1.1.2 IQSDA32 ........
  • Page 4 6.2 Control Window ..........27 © Issue 2 Rev 3 Page 4 2015 Snell Limited...
  • Page 5: Introduction

    3 Gbit/s operation when required. 1.1.2 IQSDA32 The IQSDA32 is a distribution amplifier for HD-SDI 3 Gbit/s, 1.5 Gbit/s or 270 Mbit/s SD-SDI signals providing 7 equalized and reclocked outputs of the input in a single width package. Its 80m 3G, 180m HD input equalization performance and non re-clocking distribution of wide-band signals make it ideal for all distribution applications.
  • Page 6: Order Codes

    IQSDA3261-1B relay bypass. IQSDA3261-1A3 3G/HD/SD-SDI Reclocking Distribution Amplifier. 1 input, 6 outputs, IQSDA3261-1B3 relay bypass. IQSDA32-3G Upgrade for IQSDA32 HD/SD-SDI Reclocking Distribution Amplifier to operate with 3 Gbit/s SDI signals. © Issue 2 Rev 3 Page 6 2015 Snell Limited...
  • Page 7: Rear Panel View

    The input signal will bypass the module and be routed to the respective output in the event Note: of module removal or power failure. 1.3.2 IQSDA32 IQSDA3247-1A(B) / IQSDA3247-1A(B)3 IQSDA3261-1A(B) / IQSDA3261-1A(B)3 The input signal will bypass the module and be routed to the respective output in the event Note: of module removal or power failure.
  • Page 8: Enclosures

    1.4.1 B-style Enclosure Enclosure order codes: IQH3B-S-0, IQH3B-S-P 1.4.2 A-style Enclosures Enclosure order code: IQH1A-S-P Enclosure order codes: IQH3A-S-0, IQH3A-S-P Enclosure order codes: IQH3A-E-0, IQH3A-E-P, IQH3A-0-0, IQH3A-0-P Enclosure order code: IQH1A-S-P © Issue 2 Rev 3 Page 8 2015 Snell Limited...
  • Page 9: Feature Summary

    IQSDA30/IQSDA32 www.snellgroup.com Introduction 1.5 Feature Summary The IQSDA30 and IQSDA32 provide the following features. 1.5.1 IQSDA30 • Dual channel Intelligent 3 Gbit/s SDI, HD-SDI and SD-SDI re-clocking distribution amplifier • Will distribute DVB-ASI and other wide-band signals • Equalizes up to 80m at 3 Gbit/s, 180m at 1.5 Gbit/s and more than 350m at 270 Mbit/s when using Belden 1694A cable •...
  • Page 10: Technical Specification

    Input 1 (2) Error Input 1 (2) Loss Input 1 (2) 3G Input 1 (2) HD Input 1 (2) SD Other Controls User Memories Name, save, and recall 16 user memories © Issue 2 Rev 3 Page 10 2015 Snell Limited...
  • Page 11 3 Gbit/s SDI, SMPTE 424M 1.5 Gbit/s HD-SDI, SMPTE 292M 270 Mbit/s SDI, SMPTE 259M-C / DVB-ASI Connector/Format BNC/ 75 Ohm panel jack on standard Snell connector panel Return Loss >-15 dB (270 Mbit/s, 1.5 Gbit/s) >-10 dB (3 Gbit/s) Output Jitter SD-SDI 0.2 UI (10 Hz) / 0.2 UI (1 kHz)
  • Page 12: Iqsda32

    IQSDA30/IQSDA32 www.snellgroup.com Technical Specification 2.2 IQSDA32 Inputs and Outputs Signal Inputs SDI Inputs Input Cable Length Up to 80 m Belden 1694A @ 3 Gbit/s Up to 180 m Belden 1694A @ 1.5 Gbit/s Up to 350 m Belden 1694A @ 270 Mbit/s...
  • Page 13 3 Gbit/s SDI, SMPTE 424M 1.5 Gbit/s HD-SDI, SMPTE 292M 270 Mbit/s SDI, SMPTE 259M-C / DVB-ASI Connector/Format BNC/ 75 Ohm panel jack on standard Snell connector panel Return Loss >-15 dB (270 Mbit/s, 1.5 Gbit/s) >-10 dB (3 Gbit/s) Output Jitter SD-SDI 0.2 UI (10 Hz) / 0.2 UI (1 kHz)
  • Page 14: Connections

    Connections 3. Connections This section describes the physical input and output connections provided by the IQSDA30 and IQSDA32. 3.1 IQSDA30 3.1.1 Inputs Serial digital input to the unit is made via 2 BNC connectors, which terminate in 75 Ohms.
  • Page 15: Iqsda32

    IQSDA30/IQSDA32 www.snellgroup.com Connections 3.2 IQSDA32 3.2.1 Inputs Serial digital input to the unit is made via a single BNC connector, which terminate in 75 Ohms. IQSDA3247-1A(B)/IQSDA3247-1A(B)3 IQSDA3261-1A(B)/IQSDA3261-1A(B)3 3.2.2 Outputs Serial digital output from the unit is made via 7 BNC connectors (6 on Relay Bypass version), which terminate in 75 Ohms.
  • Page 16: Card Edge Leds

    • Both LEDs illuminated – 3 Gbit/s • Left LED only illuminated – 1.5 Gbit/s • Right LED only illuminated – 270 Mbit/s • Both LEDs off – Rate unknown © Issue 2 Rev 3 Page 16 2015 Snell Limited...
  • Page 17: Controlling The Iqsda30/32 From The Rollcall Control Panel

    The first two lines of the Unit Status display the input status, detected rate, and input selection method for Input 1. The third and fourth lines of the Unit Status display the same information for Input 2. © Issue 2 Rev 3 Page 17 2015 Snell Limited...
  • Page 18: Input

    If the On Input Loss / Mute option is selected, the output will be muted whenever a recoginized rate is not detected; or, if the On Input Loss / Pass option is selected, any signal standard, frequency, etc... will pass through. © Issue 2 Rev 3 Page 18 2015 Snell Limited...
  • Page 19: Output 1

    5.2.3 Input 2 SDI Rate and Output 2 (IQSDA30 only) These options are the same as the Input 1 SDI Rate and Output 1 options but are applied to Input 2 and Output 2. © Issue 2 Rev 3 Page 19 2015 Snell Limited...
  • Page 20: Memory 1-16

    To recall a memory: • In the Recall Memory column, select the memory to recall. The recalled settings will be applied and the memory name will appear in the Last Recalled Memory section. © Issue 2 Rev 3 Page 20 2015 Snell Limited...
  • Page 21: Logging

    Log Enable: Select the check boxes that correspond to the parameters for which log information should be collected. • Log Field: Displays the name of the logging field. • Log Value: Displays the current log value. © Issue 2 Rev 3 Page 21 2015 Snell Limited...
  • Page 22: Log Field Descriptions

    Valid values are HD /SD SDI. INPUT_N_STATE= Displays the current input state. Valid values are: • • WARN • FAIL INPUT_N_SDRATE= Displays the current bit rate for the serial data input. © Issue 2 Rev 3 Page 22 2015 Snell Limited...
  • Page 23: Rolltrack

    Input N Bitrate Un. Received bitrate is unknown. Using Config 1 Configuration 1 is selected. Using Config 2 Configuration 2 is selected. Using Restart Conf Restart configuration (3) is selected. © Issue 2 Rev 3 Page 23 2015 Snell Limited...
  • Page 24: Rolltrack Address

    RollTrack message has not been correctly acknowledged at the destination unit. This could be because the destination unit is not of the type specified. Disabled RollTrack sending is disabled. © Issue 2 Rev 3 Page 24 2015 Snell Limited...
  • Page 25: Setup

    The Factory Defaults button enables the module settings to be reset to their factory defaults. Resetting the module to its factory defaults also clears all the saved memory settings. Note: © Issue 2 Rev 3 Page 25 2015 Snell Limited...
  • Page 26: Restart

    To change the name of Input 1 or Input 2, type the name in the text field and click S. To return the name to its factory default, click P. © Issue 2 Rev 3 Page 26 2015 Snell Limited...
  • Page 27: Controlling The Iqsda30/32 From An Active Front Panel

    (white-on-black) indicating that the mode is active. If the mode is not available for selection the text will remain normal. © Issue 2 Rev 3 Page 27 2015 Snell Limited...

This manual is also suitable for:

Iqsda30

Table of Contents