Summary of Contents for Balluff BIS L-405-037-00*-05-MU

  • Page 1 Compact Processor BIS L-405-033-00_-05-MU BIS L-405-037-00_-05-MU Deutsch – bitte wenden! No. 834 487 D/E • Edition 0709 Specifications subject to change. Replaces edition 0605. Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.F. Germany Phone +49 7158 173-0 Fax +49 7158 5010 www.balluff.com...
  • Page 2: Table Of Contents

    BIS L-405-03_-00_-05-MU_834487_E_0709.p65 Contents Safety Notes ..........................4 Introduction BIS L-405 Identification System ................ 5/6 Application BIS L-405 Processor ..................7-12 CRC data check with BIS L-405-037-... Processor ............13/14 Installation L-405 ......................... 15/16 Installation L-405-...-001-......................17 Installation L-405-...-002-......................18 Installation L-405-...-003-...
  • Page 3: Introduction Bis L-405 Identification System

    BIS L-405-03_-00_-05-MU_834487_E_0709.p65 Introduction BIS L-405 Identification System This manual is intended to guide the user in installing and commissioning the components in the BIS L-405 identification system, so that start-up time is reduced to an absolute minimum. The BIS L-405 identification system belongs to the category of Principle read-only, non-contacting systems.
  • Page 4: Application Bis L-405 Processor

    BIS L-405-03_-00_-05-MU_834487_E_0709.p65 Application BIS L-405-... Processor Signal description Tag Present (TP): Indicates a data carrier in the field. Address (ADR): Signal change outputs the next data carrier address. Strobe (STR): This signal acknowledges the data output on the parallel interface. ReStart: Deletes the data memory in the BIS L-405 and sets all data outputs to 0.
  • Page 5 BIS L-405-03_-00_-05-MU_834487_E_0709.p65 Application BIS L-405-... Processor Restart when data If a ReStart is detected while a data carrier is in the active zone of the read head, the data carrier is present outputs are switched to 0 and acknowledged with STR. As soon as ReStart goes low again, first the STR signal is inverted as acknowledgement and the data carrier is read out again.
  • Page 6 BIS L-405-03_-00_-05-MU_834487_E_0709.p65 Application BIS L-405-... Processor Cable test The cable test can be used to check the wiring of the outputs. "ReStart" is switched to "high" and acknowledged with STR. The first data output D0 is not switched until the ADR signal changes.
  • Page 7: Crc Data Check With Bis L-405-037

    BIS L-405-03_-00_-05-MU_834487_E_0709.p65 CRC data check with BIS L-405-037-... Processor The BIS L-405-037-... processor checks for correctness of the data read using a CRC_16 checksum. This CRC_16 checksum is located in Byte 3 and Byte 4 of the data carrier. This ensures especially high data integrity.
  • Page 8: Installation L-405

    BIS L-405-03_-00_-05-MU_834487_E_0709.p65 BIS L-405 Installation Installation When installing two BIS L-405 on a metal base, there is normally no mutual interference. If BIS L-405 a metal frame is located in an unfavorable location, problems may result when reading out the data carriers. In this case the read distance will be reduced to 80 % of the maximum value.
  • Page 9 BIS L-405-03_-00_-05-MU_834487_E_0709.p65 BIS L-405-...-001-... Installation Clear zone and Clear zone distances ø5.3 Power Active surface Set screw Specifications by Speeds: For v = 0 (static condition) data carrier Specifications by data carrier At read BIS L-405-033-001-... Offset to center axis at (installed in clear Read distance...
  • Page 10 BIS L-405-03_-00_-05-MU_834487_E_0709.p65 BIS L-405-...-003-... Installation Installation BIS L-405-...-003-... Standard length 5 m (max. 20 m) Specifications by Speeds: For v = 0 (static condition) data carrier Specifications by At read data carrier Offset to center BIS L-405-033-003-... distance Speed [m/s] (installed in clear axis at distance of: Read...
  • Page 11 BIS L-405-03_-00_-05-MU_834487_E_0709.p65 BIS L-405 Installation Lead assignments BIS L-503-... Connection for Description Color +24 V DC SUPPLY VOLTAGE 0 V DC BLUE Bit 0 WHITE Bit 1 BROWN Bit 2 GREEN Bit 3 YELLOW Bit 4 GRAY OUTPUTS Bit 5 ROSE Bit 6 BLACK...
  • Page 12: Reorienting And Rotating The Read Head

    BIS L-405-03_-00_-05-MU_834487_E_0709.p65 BIS L-405 Reorienting and Rotating the Read Head Reorienting the read - Remove the two screws on the read head base head - Turn the read head module 180° - Tighten both screws Rotating the read - Unscrew the set screw head - Read head module can be rotated stepless (complete with read head base) to the desired position (range: 270°)
  • Page 13: Technical Data

    2004/108/EC (EMC Directive) and the EMC Law. In our EMC Laboratory, which is accredited by the DATech for Testing Electromagnetic Compatibility, we have verified that Balluff products meet the EMC re- quirements of the following Generic Standards: EN 61000-6-4 (Emission), EN 61000-6-2 (Noise Immunity).
  • Page 14: Appendix, Ascii Table

    BIS L-405-03_-00_-05-MU_834487_E_0709.p65 Appendix, ASCII Table Deci- Control Deci- Control Deci- Deci- Deci- Deci- ASCII ASCII Hex ASCII Hex ASCII Hex ASCII Hex ASCII Code Code Ctrl @ Ctrl V 107 6B Ctrl A Ctrl W 108 6C Ctrl B Ctrl X 109 6D Ctrl C Ctrl Y...