Warnings - Graco Husky 3300 Repair Parts

Air-operated diaphragm pump
Table of Contents

Advertisement

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. When
these symbols appear in the body of this manual, refer back to these Warnings. Additional, product-specific warnings
may be found throughout the body of this manual where applicable.
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help
prevent fire and explosion:
Use equipment only in well ventilated area.
Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop
cloths (potential static arc).
Keep work area free of debris, including solvent, rags and gasoline.
Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes
are present.
Ground all equipment in the work area. See Grounding instructions.
Use only grounded hoses.
Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they
are antistatic or conductive.
Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment
until you identify and correct the problem.
Keep a working fire extinguisher in the work area.
Route exhaust away from all ignition sources. If diaphragm ruptures, fluid may be exhausted with air.
Static charge may build up on plastic parts during cleaning and could discharge and ignite flammable
vapors. To help prevent fire and explosion:
Clean plastic parts only in a well ventilated area.
Do not clean with a dry cloth.
Do not operate electrostatic guns in equipment work area.
PRESSURIZED EQUIPMENT HAZARD
Fluid from the equipment, leaks, or ruptured components can splash in the eyes or on skin and cause
serious injury.
Follow the Pressure Relief Procedure when you stop spraying/dispensing and before cleaning,
checking, or servicing equipment.
Tighten all fluid connections before operating the equipment.
Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
3A0411A
WARNING
Warnings
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ti16556aTi16561aTi17454a

Table of Contents