Replacement; Minimum Requirements - golmar RD-V2PLUS Instruction Manual

Digital repeater
Table of Contents

Advertisement

REPLACEMENT

The Golmar
V2PLUS
without polarity), designed to new installations and to replace existing audio door entry systems in both
apartment blocks and villas.
In installation for replacement it is necessary a detailed study of the existing installation before installing
the system. To check that your installation complies with the system s minimum recommended
requirements, please read carefully the following chapters, which provide details of the checks to be done.

MINIMUM REQUIREMENTS

Before installing this system, we must ensure that the existing installation complies with the following
requirements:
-The installation must be realized by multipaired cable, (not to use single-wire cables).
-The wires must not be spliced, frayed, nor touch metal parts, and must not vary in cross
section throughout the entire installation.
-The entire installation must be at least 40cm away from any other installation otherwise there
is a risk that the audio and video signal be exposed to interference, or that the system
does not work correctly.
-All branch connections must be made using D4L-V2PLUS or D1L-V2PLUS distributors.
-Each floor must have physical space to situate the distributor/s, in case they are necessary.
-Each apartment must have sufficient space to install the video system monitor.
-Maximum installation distance it will depend on the section and the installed cable (see pages 50-51).
-Installations with independent more common wires,
connect the independent ones).
-1 access door panel, (up to 3 access door panel with
-Up to 32 (monitors, telephones or call repeaters) and apartments without using converters, repeaters
or multiplexers.
-Up to 16 (monitors, telephones or call repeaters) and apartments in daisy chain installations without
distributor, per installation without using converters, repeaters or multiplexers.
-Up to 3 elements (monitors, telephones or call repeaters S-45) per apartment.
-Installations with more than 32 elements or it is wanted to increase the distance in the riser (it needs the
use of the
RD-V2PLUS
-Installations with more than 32 elements or 1 riser (it needs the use of the multiplexer
-Installations with general door panels (it needs the use of the
-Before connecting the system s power supply, we must ensure that there are
relays or call repeaters in the apartments.
units that are compatible with the new system, otherwise the installation could be seriously
damaged or burnt.
If any of the first three requirements are not met, it will be necessary to replace the installation riser.
If the branch connections to the apartments are in good condition, their replacement will not be necessary.
*
If replacing the installation riser, use the Golmar cable
*
SECTIONS CHART
BUS, D
+, -
(d.c lock release)
(a.c lock release)
Do not use different types of cable in the same installation
*
Maximum distance of 150 m. between door panel and last monitor/telephone and between
( ) 2
monitors/telephones of different apartments connected to door panel.
video door entry system is a digital system with simplified installation (2 wire bus
).
'
One access and one riser
( ) 2
Terminal
CV1,CV2
CV1,CV2, ~, ~
only use the common wires
multiplexer).
MC-V2PLUS
CD-V2PLUS
If so, we must disconnect them or replace them with
and the next sections:
RAP-2150
Door
panel-Monitor P .S.- Door panel
150m.
( ) 1
RAP-2150
1,5mm²
(contact with our technical support department)
'
(separate and do not
MC-V2PLUS
converters).
NO old parallel units,
Door panel - CV
50m.
50m.
0,5mm²
1mm²
1mm²
1
0
).
.
Continue.

Advertisement

Table of Contents
loading

Table of Contents