Cód. 50123467
Digital
Repeater
RD-V2PLUS
Instructions manual
TRD-V2PLUS ML rev.0114

Advertisement

Table of Contents
loading

Summary of Contents for golmar RD-V2PLUS

  • Page 1 Cód. 50123467 Digital Repeater RD-V2PLUS Instructions manual TRD-V2PLUS ML rev.0114...
  • Page 2: Table Of Contents

    When starting the equipment for the first time, or after a modification, the system will remain inactive for around 45 seconds due to the initial busy channel time Use Golmar cable in the system...
  • Page 3: Safety Precautions

    Tekna V2Plus Color V.02 repeater. IMPORTANT: In the output of a distributor cannot be connected another distributor Use Golmar cable in the RAP-2150 V2Plus system...
  • Page 4: Operation Modes

    For characteristics, sections and distances see the corresponding product manual. Note: If the repeater/multiplexer is at a distance less than 50 meters from the door panel, place in the door panel the dip gain SW1-6 to OFF . Bus: Golmar RAP-2150 cable.
  • Page 5 D: Repeater in daisy chain (32 elements for riser / 600 meters): 200m 150m 150m 100m ( ) 1 Apartments EL500/V2Plus MC-V2Plus RD-V2Plus RD-V2Plus D1L or D4L-V2Plus Up to 32 monitors 25m. 0,75 mm 1,5 mm 1,5 mm 1,5 mm FA-V2Plus FA-V2Plus FA-V2Plus FA-V2Plus Bus: Golmar RAP-2150 cable. Continue...
  • Page 6 For characteristics, sections and distances see the corresponding product manual. Note: If the repeater/multiplexer is at a distance less than 50 meters from the door panel, place in the door panel the dip gain SW1-6 to OFF . Bus: Golmar RAP-2150 cable.
  • Page 7: Operation Modes

    1,5 mm FA-V2Plus FA-V2Plus Up to 1 RD-V2Plus for each distributed output of D1L or D4L-V2Plus distributor. For this operation mode contact our technical support department. ( ) 1 Important: Do not exceed the max. monitors/telephones connected to a door panel/multiplexer/repeater, or the distances indicated for door panel/multiplexer/repeater and last monitor and monitors between different apartments connected to door panel/multiplexer/repeater.
  • Page 8: Description Of The Repeater

    DESCRIPTION escription of the repeater. Autodiagnostic LEDs. Reset button 'P1', for short-circuit Bus (riser where repeater is connected). Label. connection block Power supply input (with FA-V2Plus power supply). DIN rail latch release. INSTALLATION etail of the repeater installation. Install the repeater in a dry and protected place without risk of drip or water projections.
  • Page 9: Autodiagnostic Leds

    AUTODIAGNOSTIC LEDS escription of autodiagnostic LEDs. The autodiagnostics LEDs are placed on the top right of the digital repeater. Green Led Fixed: Correct operation. Blinking: Riser communicating. : Riser not functioning due to a short-circuit in the riser * between the bus wires. If the short circuit is eliminated before Red Led 2 minutes (approx.), the repeater will...
  • Page 10: Replacement

    If any of the first three requirements are not met, it will be necessary to replace the installation riser. If the branch connections to the apartments are in good condition, their replacement will not be necessary. If replacing the installation riser, use the Golmar cable and the next sections:...
  • Page 11: Installation Of Replacement

    - Maximum distance between multiplexer in daisy chain and the last monitor B/W and between monitors of different apartments (in the same riser) connected to multiplexer in daisy chain will be:100m. Golmar has a special cable for this system, its reference number is . The use of this cable...
  • Page 12: Cable, Sections And Distances Chart (Several Accesses And Risers)

    4 par UTP Cat 5 0,18x4= 0,72mm : The distance to increase with , it will depend on the installed cable section. IMPORTANT repeater . See examples of installation diagrams, page 55-56 and 58. ontact our technical support department Use Golmar RAP-2150 cable, for new installations.
  • Page 13: Installation Diagrams

    Tekna V2Plus PA PB BUS IN BUS OUT Tekna V2Plus PA PB BUS IN BUS OUT FA-V2PLUS RD-V2Plus Configuring the end of line in the last monitor. - - + BUS IN BUS OUT M =Master. Main V2Plus door panel FA-V2PLUS...
  • Page 14: Video Door Entry System With Distributor And 2 Repeaters In Daisy Chain

    D4L-V2Plus Tekna V2Plus Tekna V2Plus F.Linea PA PB PA PB BUS IN BUS OUT BUS IN BUS OUT FA-V2PLUS RD-V2Plus - - + BUS IN BUS OUT Main D4L-V2Plus Tekna V2Plus Tekna V2Plus F.Linea PA PB PA PB BUS IN...
  • Page 15 INSTALLATION DIAGRAMS ideo door entry system with distributor, 2 repeaters and d.c lock release. See example 'C' and important notes in 'operation modes' (pág. 43). The installation diagram shows the connection of a video door entry system with one door panel to access the building with distributors, 2 repeaters in daisy chain and d.c lock release.
  • Page 16 PA PB PA PB BUS IN BUS OUT BUS IN BUS OUT BUS IN BUS OUT FA-V2PLUS FA-V2PLUS RD-V2PLUS RD-V2PLUS - - + - - + BUS IN BUS OUT BUS IN BUS OUT Main Main MC-V2PLUS FA-V2PLUS - - +...
  • Page 17 F.Linea PA PB PA PB BUS IN BUS OUT BUS IN BUS OUT FA-V2PLUS FA-V2PLUS RD-V2PLUS RD-V2PLUS - - + - - + BUS IN BUS OUT BUS IN BUS OUT Main Main Insert a 120 ohm end of line resistor in the last distributor.
  • Page 18: Special Connections

    PA PB PA PB BUS IN BUS OUT BUS IN BUS OUT R.120 FA-V2PLUS FA-V2PLUS D4L-V2Plus RD-V2PLUS RD-V2PLUS F.Linea - - + - - + BUS IN BUS OUT BUS IN BUS OUT Main Main To riser 2 To riser 3 V2Plus door panel M =Master.
  • Page 19 BUS OUT BUS IN BUS OUT Insert a 120 ohm end of line resistor in the last distributor. R.120 FA-V2PLUS FA-V2PLUS D4L-V2Plus RD-V2PLUS RD-V2PLUS F.Linea - - + - - + BUS IN BUS OUT BUS IN BUS OUT Main Main...
  • Page 20 1141 Budapest, Fogarasi út 77. 1095 Budapest, Mester utca 34. Tel.: *220-7940, 220-7814, 220-7959, Tel.: *218-5542, 215-9771, 215-7550, 220-8881, 364-3428 Fax: 220-7940 216-7017, 216-7018 Fax: 218-5542 Mobil: 30 531-5454, 30 939-9989 Mobil: 30 940-1970, 30 959-0930 www.golmar.hu E-mail: info@delton.hu Web: www.delton.hu...