Max/Min Function - LaserLiner ClampMeter XP Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
PEAK function (voltage peak function)
13
The PEAK function detects the highest positive and lowest negative peak in an AC voltage or AC
current wave form. The measured values are updated each time a higher positive or lower negative
PEAK is detected.
1.
2.
2 sec
Activate PEAK
"PMAX"
Briefly press the PEAK/INRUSH button to switch between PMAX and PMIN. To return to normal
operation, keep the PEAK/INRUSH button pressed until „AUTO" appears on the LC display.
INRUSH function (current peak function)
14
The INRUSH function detects and displays current peaks that typically occur when switching on motors
or other devices. To activate the function, briefly press the PEAK/INRUSH button. „INRUSH" appears
together with the detected inrush current on the LC display. To return to normal operation, briefly press
the PEAK/INRUSH button.
REL function (comparison measurement)
15
The comparison measurement function takes a measurement relative to a previously saved reference
value. This enables the difference between the current measured value and the saved reference value to
be displayed. Press the „REL" button whilst a reference measurement is being taken in the corresponding
measuring function. The display now shows the difference between the current measurement and the
set reference value. Press the „REL" button again to deactivate the function.
HZ function
16
To select the frequency, with the measuring device set to AC voltage or AC current, keep the REL/HZ/%
button pressed until „Hz" appears on the LC display. To display the inrush cycle, again keep the REL/
HZ/% button pressed until „%" appears on the LC display. Press the „REL" button again to deactivate
this function.

MAX/MIN function

17
The MAX/MIN function shows the highest and lowest measured values. The measured values are
updated each time a higher or lower measurement is recorded. To activate the function, briefly press
the MAX/MIN button. „MAX" appears together with the highest value on the LC display. By briefly
pressing the MAX/MIN button, the device switches from MAX to MIN, from MIN to the current measured
value and from the actual measured value to MAX. „MIN" appears when the lowest measured value
is displayed and „MAX MIN" appears when the current measured value is displayed. Keep the MAX/MIN
button pressed to exit MAX/MIN function and return to normal operation.
"PMAX"
Highest positive peak
ClampMeter XP
3.
4.
1 sec
Switch to
"PMIN"
"PMIN"
Lowest negative peak