Input Protection - LaserLiner MultiMeter XP Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 16
Function
AC current
DC current
Function
AC voltage
AC+DC voltage
LOW Z voltage AC/DC
DC voltage
Resistance, capacitance, diode
check, continuity, temperature
All accuracy ratings in AC ranges are specified for 5%...95% of measured value
Diode test
Continuity test
LCD
Measurement range
Input resistance
Protection class
Overvoltage category
Pollution degree
Operating conditions
Storage conditions
Radio module operating data
Power supply
Dimensions (W x H x D)
Weight (incl. batteries)
EU directives and disposal
This device complies with all necessary standards for the free
movement of goods within the EU.
This product is an electric device and must be collected separately
for disposal according to the European Directive on waste electrical
and electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=mumexp
Range
Range
45 Hz ... 1000 Hz
50 Hz ... 400 Hz
50 Hz ... 400 Hz
50 Hz ... 400 Hz
Test current/voltage 1 mA /
open circuit voltage < 3 V DC typical
Response threshold < 30Ω, Test current < 1 mA
0 ... 6000
3 measurements/sec.
10 MΩ (VDC, VAC, V AC+DC), 3 kOhm (VDC Low Z, VAC Low Z)
II, double insulation
CAT III - 1000V, CAT IV - 600V
2
0 ... 40°C, 75%rH, no condensation, max. altitude 2000 m
-10 ... 60°C, 80%rH, no condensation
Bluetooth LE 4.x interface
Frequency band: ISM band 2400–2483.5 MHz, 40 channels
Transmission power: max. 10 mW
Bandwidth: 2 MHz
Bit rate: 1 Mbit/s; Modulation: GFSK/FHSS
4 x AAA 1.5 Volt batteries
75 x 170 x 48 mm
416 g
MultiMeter XP
Max. input
10 A
10 A

Input protection

1000V AC rms or 1000V DC
600V AC rms or 600V DC
600V AC rms or 600V DC
600V AC rms or 600V DC
600V AC rms or 600V DC
29
EN

Advertisement

Table of Contents
loading

Table of Contents